Troubleshooting - Velex VX326 Instruction Manual

Gauge hole receivers
Table of Contents

Advertisement

ISSUE
Unit will not turn
on (no power)
Unit has power
(but no sound)
Unit blows fuses
Trouble Shooting
OPTIONS
Cause: Yellow/red wire not connected or incorrect voltage
Action: Check connections for proper voltage (11-16V DC)
Cause: Black wire not connected
Action: Check connection to ground
Cause: Fuse blown
Action: Replace the fuse
Cause: Speaker wire not connected
Action: Check connections at speakers
Cause: One or more speaker wires touching each other
or touching chassis ground
Action: Insulate all bare speaker wires from each other
and chassis ground
Cause: Yellow/red wire touching chassis ground
Action: Check for pinched wire
Cause: Speaker wires touching chassis ground
Action: Check for pinched wire
Cause: Incorrect fuse rating
Action: Use fuse with correct rating