Figure 6-12
Carefully feed the main rotor leads through
the hole as the exciter armature is removed.
(Figure 6-13.)
Figure 6-13
CAUTION:
DO NOT TIGHTEN THE PULLER
BOLT BEYOND THE END OF THE
THREADS. IF A BOLT WITH
SUFFICIENT THREAD LENGTH
CANNOT BE FOUND, USE A PIECE
OF THREADED ROD WITH A NUT
WELDED ON THE END.

PMG STATOR REMOVAL

1. Remove exciter armature. (Follow
instructions found earlier in this section.)
2. Remove the PMG output leads from the
capacitor (Figure 6-14) and loosen all cable
ties so the leads can be removed with the
PMG stator.
Figure 6-14
3. Note the position of the PMG stator leads
that exit at the left inboard side or mark the
stator so it can be reinstalled in the same
position.
4. Remove the four mounting cap screws.
(See Figure 6-15.)
Figure 6-15