Temperature Compensation

This function allows you the capability to adjust the temperature compensation offset of any indoor unit. The adjusted value is
programmed into the EEPROM.
Series
IDU
3X3 Cassette
AL24LP2VHA
3X3 Cassette
AL36LP2VHA
3X3 Cassette
AL48LP2VHA
2X2 Cassette
AB09SC2VH*
2X2 Cassette
AB12SC2VH*
2X2 Cassette
AB18SC2VH*
Pro Duct
AM24LP2VHA
Pro Duct
AM36LP2VHA
Pro Duct
AM48LP2VHA
Mid-Static Duct
USYM09UCDSA
Mid-Static Duct
USYM12UCDSA
Mid-Static Duct
USYM18UCDSA
Mid-Static Duct
USYM24UCDSA
Slim Duct
AD07SL2VH*
Slim Duct
AD09SL2VH*
Slim Duct
AD12SL2VH*
Slim Duct
AD18SL2VH*
Highwall
AW07EH2VHA
Highwall
AW09EH2VHA
Highwall
AW12EH2VHA
Highwall
AW18EH2VHA
Highwall
AW07LC2VHB
Highwall
AW09LC2VHB
Highwall
AW12LC2VHB
Highwall
AW18LC2VHB
Console
USYF09UCDWA
Console
USYF12UCDWA
Console
USYF18UCDWA
Guide 1
1. Install the grille assembly and connect the power cable.
2. Unplug the wired controller.
3. Connect power to the unit.
4. Press the ON/OFF button on the remote control (HBS-01).
5. (Ignore this step if the display temperature is already
then press confirm.
6. Open the front cover of the remote controller, and press the LIGHT button 12 times in 7 seconds.
7. The panel will beep 4 times and display an "A".
8. Press the LIGHT button once to confirm. The display will read "A0".
9. Press the button TEMP. or TEMP. until the display shows "A5".
10. Press the LIGHT button once to confirm. The display will read "0b".
11. Press the button TEMP. or TEMP. to scroll through the listed
Codes. Each code is associated with a corresponding compensation
value (see table below). For example, if you want make the
temperature invalid, scroll it to 0F.
12. Press the LIGHT button once to confirm. The display will read "A5".
13. Press the ON/OFF button on the remote control to save the changes.
J-4
Special Functions
IDU PCB part number
Haier
GEA
0151800208
WJ26X23559
0151800208
WJ26X23559
0151800208
WJ26X23559
0151800208A
WJ26X23785
0151800208A
WJ26X23785
0151800208A
WJ26X23785
0151800267
WJ26X23580
0151800106E
WJ26X23585
0151800106E
WJ26X23586
0151800580
WJ26X27175
0151800580
WJ26X27175
0151800580
WJ26X27175
0151800580
WJ26X27175
0151800175A
WJ26X23178
0151800175A
WJ26X23178
0151800175A
WJ26X23178
0151800175A
WJ26X23178
A0011001066
WJ26X25213
A0011001066
WJ26X25213
A0011001066
WJ26X25213
A0011007590
WJ26X25413
A0011800281CA
WJ26X23928
A0011800281CA
WJ26X23928
A0011800281CA
WJ26X23928
A0011800281FA
WJ26X23929
0151800579
WJ26X27223
0151800579
WJ26X27223
0151800579
WJ26X27223
C,) Press MENU/OF button to switch the display temperature to
O
TROUBLESHOOTING & REFERENCES
Controls Needed
Controller
IR Reciever
YR-HBS01
\
YR-HBS01
\
YR-HBS01
\
YR-HBS01
\
YR-HBS01
\
YR-HBS01
\
YR-HBS01
RE-02(CN21)
YR-HBS01
RE-02(CN29)
YR-HBS01
RE-02(CN29)
YR-HG
RE-02(CN29)
YR-HG
RE-02(CN29)
YR-HG
RE-02(CN29)
YR-HG
RE-02(CN29)
YR-HBS01
RE-02(CN29)
YR-HBS01
RE-02(CN29)
YR-HBS01
RE-02(CN29)
YR-HBS01
RE-02(CN29)
YR-HG
\
YR-HG
\
YR-HG
\
YR-HG
\
YR-HG
\
YR-HG
\
YR-HG
\
YR-HG
\
YR-HG
\
YR-HG
\
YR-HG
\
Guide
Wired Controller
Reference
Unplug
Chart 1
Unplug
Chart 1
Unplug
Chart 1
Unplug
Chart 3
Unplug
Chart 3
Unplug
Chart 3
Unplug
Chart 2
Unplug
Chart 2
Unplug
Chart 2
Unplug
Chart 4
Unplug
Chart 4
Unplug
Chart 4
Unplug
Chart 4
Unplug
Chart 2
Unplug
Chart 2
Unplug
Chart 2
Unplug
Chart 2
\
Chart 4
\
Chart 4
\
Chart 4
\
Chart 4
\
Chart 4
\
Chart 4
\
Chart 4
\
Chart 4
\
Chart 4
\
Chart 4
\
Chart 4
C,
O

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents