Hide thumbs Also See for RHPS Series:

Advertisement

RHPS Series
LPRD10,15
User Manual
Read the complete manual before installing and using the regulator.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RHPS Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Swagelok RHPS Series

  • Page 1 RHPS Series LPRD10,15 User Manual Read the complete manual before installing and using the regulator.
  • Page 2: Table Of Contents

    WARNING Before removing a regulator from the system for service, you must ▪ depressurize system ▪ purge the system to remove any residual system media left in the regulator. Contents Introduction ............................... 3 Installation ..............................5 Operation ..............................7 Maintenance .............................. 8 Testing ...............................
  • Page 3: Introduction

    Introduction Represenative drawings of the standard LPRD10 body diaphragm plate dome o-ring top cover bodyplug back-up ring bonded seal valve case o-ring bleed fitting valve stem o-ring tube o-ring seal ring male connector seat tube valve spring ring male connector bodyplate socket head cap screw pilot regulator...
  • Page 4 Represenative drawings of the standard LPRD15 body diaphragm dome diaphragm plate top cover bodyplug o-ring bonded seal valve case o-ring bleed fitting push rod o-ring tube valve insert seal ring male connector valve screw tube seat ring male connector valve spring socket head cap screw pilot regulator bodyplate...
  • Page 5: Installation

    Installation WARNING When installing a Swagelok self-venting regulator, position the vent connection or line away from operating personnel. Operating personnel must protect themselves from exposure to system fluids CAUTION Do not use the regulators as a shutoff device. The preferred mounting position of the regulator is horizontal with the dome facing upwards.
  • Page 7: Operation

    Operation Note: All handle directions are when viewed from above.  Outlet and control pressure settings are obtained by adjusting the handle. For dome-loaded regulators settings are obtained by adjusting the adjusting screw with a 12 mm open end wrench. ...
  • Page 8: Maintenance

     All parts must be clean and undamaged before starting assembly.  Swagelok recommends replacing all o-rings and the diaphragm before assembly.  All threaded parts must be lightly lubricated before assembly, this to avoid galling of threads. All o-rings need to be lightly lubricated to improve the lifetime of the o-ring and the performance of the ...
  • Page 9: Troubleshooting

    The outlet pressure has changed without adjusting the dome pressure. Cause: Changes to the inlet pressure will result in changes to the outlet pressure. Solution: Maintain a constant inlet pressure to the regulator. See section “operation” about dependency. For additional information, see www.swagelok.com. ® Snoop Swagelok, – Swagelok Company ©...

This manual is also suitable for:

Lprd10Lprd15

Table of Contents