3.7 Replacement of the
connection cable
The replacement of electric
cable must be carried out
exclusively by the service
force centre or by personnel
with similar competencies, in
accordance with the current
regulations.
To replace the connection
cable use only H03V2V2-F
T90 or equivalent type.
Make sure that the cable
section is applicable to the
voltage load and the working
temperature. The yellow/
green earth wire (B) must be
approximately 2 cm longer
than the live and neutral wire
(A).
1. Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth symbol
, or coloured green and yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the
letter 'N' or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the
letter 'L'. It must always be connected
to the network phase. There must be
no cut or stray strands of wire
present. The cord clamp must be
correctly attached to the outer
sheath.
A
B