Download Print this page

Primetime 2BL455 Instruction Manual page 5

Advertisement

FUSE REPLACEMENT FOR FIXTURES
WITH DETACHABLE POWER CORDS.
DIRECTIONS
Fixtures equipped with detachable power cords contain fuses which are rated at ten amps
@ 250 Vac. To replace fuse remove power cord exposing the receptacle as shown in figure
A. Make certain there are no other cords attached to the fixture. Using a small flat screw
driver, pry up the fuse holder shown in figure B. Replace the fuse in the active slot and
snap the fuse holder back into place. Use only fast acting type 217, 5 x 20 mm , 10 amp
fuses.
black
10 A fuse
CAUTION
Fused power out receptacle to be used for fluorescent studio lights only. Maximum
string wattage is 800. Fast acting fuse type 217, 5 x 20 mm , 10 Amps, 250 V.
fusedir.ai
9-08
A
LINE POWER SCHEMATIC
switch
2 lamp ballast
switch indicator light
B
spare
active fuse
fused power out
PL Systems, Inc.10529 Olympic Drive
Dallas, TX 75220
white
(214)-393-5998.