Two-stage, variable-speed ecm gas furnace up to 96% afue heating input: 40,000–120,000 btu/h
Hide thumbs Also See for ACVC96:

Advertisement

ACVC961205DNA
Cooling Speeds
( @ .1" - .8" w.c. ESP)
Tap
Adjust
Minus 10%
Minus 5%
A
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
B
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
C
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
D
Normal
Plus 5%
Plus 10%
Notes
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
Installation is to be adjusted to obtain temperature rise within the range specified on the rating plate.
Minimum Filter Sizes
ACVC96
0403BNA
Filter Size (in²) (Qty)
Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located.
SS-ACVC96
High-Stage
Low-Stage
CFM
CFM
769
486
811
513
854
540
897
567
939
594
1,011
783
1,067
827
1,123
870
1,179
914
1,235
957
1,259
900
1,329
950
1,399
1,000
1,469
1,050
1,539
1,100
1,624
1,112
1,714
1,173
1,804
1,235
1,894
1,297
1,984
1,359
ACVC96
0603BNA
(2) 10 x 20 or (1) 16 x 25 (top return)
www.amana-hac.com
ACVC961205DNA
(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)
Tap
Adjust
Minus 10%
Minus 5%
A
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
B
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
C
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
D
Normal
Plus 5%
Plus 10%
ACVC96
ACVC96
0804CNA
1005CNA
(1) 14 x 20 (bottom) or
(1) 20 x 25 (top return)
ACVC96 Airflow Data (cont.)
Heating Speed
High-Stage
Low-Stage
Rise
CFM
CFM
1,570
1,156
1,657
1,220
1,744
1,284
1,831
1,348
1,918
1,412
1,644
1,179
1,736
1,245
1,827
1,310
1,918
1,376
2,010
1,441
1,674
1,215
1,767
1,283
1,860
1,350
1,953
1,418
2,046
1,485
1,726
1,249
1,822
1,319
1,918
1,388
2,014
1,457
2,110
1,527
ACVC96
1205DNA
(°F)
n/a
64
61
58
56
65
61
58
56
53
64
60
57
55
52
62
59
56
53
51
7