Cabletron Systems TRRMIM-2AT Installation Manual page 20

Active token ring repeater modules
Hide thumbs Also See for TRRMIM-2AT:
Table of Contents

Advertisement

Cable Type
UTP
Category 3
Category 4
Category 5
Type 3 Media Filter
When connecting token ring devices that are not equipped with a
Type 3 Media Filter to a UTP port, a Type 3 Media Filter, such as the
Cabletron Systems TRMF or TRMF-2, must be installed in line with
the lobe cable at the connection to token ring station.
Multi-Mode Fiber Optic Network Requirements
When connecting a Fiber Optic Link Segment to TRRMIM-F2T or a
TPIM-F2, the following network requirements must be met:
• Cable Type - The cable must be one of the following multi-
mode fiber optic media:
-
50/125 m fiber optic cabling.
-
62.5/125 m fiber optic cabling.
-
100/140 m fiber optic cabling.
• Attenuation - The fiber optic cable must be tested with a fiber
optic attenuation test set that is adjusted for an 850 nm
wavelength. This test verifies that the signal loss in a cable is
within an acceptable level:
REQUIREMENTS/SPECIFICATIONS
Table 2-6 Maximum Lobe Length
Maximum Lobe Length
4 Mbit/s
150 meters
(492 feet)
200 meters
(656 feet)
250 meters
(820 feet)
16 Mbit/s
85 meters
(279 feet)
100 meters
(328 feet)
120 meters
(394 feet)