iGrow 800 Quick Setup Guide
SETTING UP SETPOINTS
With the iGrow 800 you can program Temperature, Relative Humidity, and C02 Setpoints.
Please view the following video and necessary steps in setting up your setpoints
IGrow 800 – Setpoint Programming
http://www.youtube.com/watch?v=7JGrg_Q1taQ
Cool Setpoint - if the temperature goes above this threshold it will enter into the cooling stages to bring the temperature
back in line within the Normal temperature range (you can have up to 6 cool stages)
Heat Setpoint - if the temperature goes below this threshold it will enter into the Heating stages to bring the temperature
back in line within the Normal temperature range (you can have up to 2 heat stages)
Humidify Setpoint - if the RH reading is below this parameter, the condition is considered too dry, and the system will go
into the humidification stage.
Dehumidify Setpoint - if the RH reading is above this parameter, the condition is considered too damp, and the system will
go into the dehumidification stage.
C02 Setpoint - if the C02ppm level is blow this parameter, the condition will be Low C02, and the system will start injecting
C02 until it reaches the Setpoint plus Deadband.
There are three options in temperature,
humidity and C02 setpoints
• DAY
• NIGHT
• DIF
DAY is active by default. NIGHT and DIF can be
turned on if desired.
To turn on a setpoint that is disabled simply
highlight Set – Night or Set – DIF hit OK
It will display that the setpoint is currently
off. To enable it on press button #5 (turn
setpoint on/off) which will then display the
night setpoint screen
Deadbands
while cooling or heating equipment may be engaged as soon as the measured temperature falls outside of the normal
range, a deadband will prevent the equipment from shutting off when the temperature returns to slightly within the normal
range. Deadbands keeps equipment from cycling on and off repeatedly due to small temperature fluctuations. The same
concept applies with humidification and dehumidification.

Advertisement

loading

Summary of Contents for Link4 iGrow 800

  • Page 1 800 Quick Setup Guide SETTING UP SETPOINTS With the iGrow 800 you can program Temperature, Relative Humidity, and C02 Setpoints. Please view the following video and necessary steps in setting up your setpoints IGrow 800 – Setpoint Programming http://www.youtube.com/watch?v=7JGrg_Q1taQ...
  • Page 2 (falls outside the Normal temperature range) the iGrow 800 will enter cooling or heating stages to bring it back in line. With the iGrow 800 you can program up to six cooling and two heating stages. These stages go from Cool 1 to Cool 6 and Heat 1 to Heat 2.
  • Page 3 SETTING UP HUMIDITY CONTROL STAGES With the iGrow 800 you can Control Relative Humility within your Greenhouse Environment. Note: Relative Humidity staging overrides Temperature staging. Here is a video link that guides you thru the control process. iGrow 400/800 Humidification Control Programming https://youtu.be/1AqGt8X6htk...
  • Page 4 IGrow 400/800 - Sensor Setup https://www.youtube.com/watch?v=wzFG-Nm0NcM IGrow 400/800 – Setpoint Programming http://www.youtube.com/watch?v=7JGrg_Q1taQ IGrow 400/800 - Setting up your equipment for Temperature & Humidity Stages. http://www.youtube.com/watch?v=7CCSDeac5hY IGrow 400/800 - Setting up your equipment ON/OFF Devices http://www.youtube.com/watch?v=YlFGSybTd_c iGrow 800 Relay Output Design and Understanding https://www.youtube.com/watch?v=czn80AFXXUk...
  • Page 5 IGrow 400/800 Save & Restore Configurations https://www.youtube.com/watch?v=33682fwe1yc iGrow 400/800 Humidification Control Programming https://youtu.be/1AqGt8X6htk iGrow 400/800 Installing the Link4 Weatherstation https://youtu.be/9rjKr0XGVxw iGrow 800 Installing the 4 Output Expansion Board https://youtu.be/ornz3yRS-vA iGrow 800 Programming Expansion Outputs https://www.youtube.com/watch?v=OjRvULzwwvk LinkConn 100 Software Overview https://www.youtube.com/watch?v=2VUD426h6Co iGrow 400/800 Connecting with The iGrow Cloud https://youtu.be/DobvKzIW56E...
  • Page 6 iGrow800 Connecting Solar Light Sensor https://www.youtube.com/watch?v=C49pp1g-LxM iGrow800 Saving History and USB Logging https://www.youtube.com/watch?v=DQ3xvABTk94 If you have any more questions or if you need assistance please give us a call at (714) 975-9474 or email us at support@link4Corp.com...