Suggested Configuration Method; C Onfiguration Menu 3 - Cabletron Systems CBUQBR User Manual

Enterasys cbuqbr interface modules: user guide
Table of Contents

Advertisement

CBUQBR
User Manual
for B2. The best practice is fill in the last complete number block, for
example in the UK the last 6 digits (or 7 digits for city numbers). The
number entered is also used for dialling additional aggregation calls
when using the CBUQHS.
If any port is not connected to the network then it must have its line
configuration deleted for both 'B' channels.
disconnected, providing the Line Configuration menu reflects this.
The Routing menu (under Configuration top menu) must be
configured to assign user port cards, e.g. CBUQHS or CBUQLS, and
their respective ports. If the line is an MSN type or single numbered
sub-address type, the desired MSN or sub-address numbers must be
entered in the Set MSN and Set Subaddress sub-menus.
'Record' number is simply a numbered list and its number has no
relation to port numbering, card slot numbering or 'B' channel
numbering).
When using with the CBUQHS one extra 'B' channel is required for
synchronisation purposes in addition to the number of 'B' channels
required for user port speed aggregation. For example for a 448kbit/s
call, seven 'B' channels are required for data plus one for
synchronisation, thus requiring 8 'B' channels - all four BRI lines
which is the maximum.
CBUQBR.

3.2.2 Suggested Configuration Method

The following is a tried and proven method of configuring the CBUQBR,
in the following order:-
1. Plug in the BRI lines into the CBUQBR, making a note of all the line
numbers versus CBUQBR ports.
2. Go to the Line configuration menu and enter each line number
against the Primary and Secondary entries, for all ports connected to
lines. The 'Primary' entry is the B1 number and 'Secondary' entry is
the B2 number. For an MSN line, enter the desired MSN number,
e.g. Primary 123451, Secondary 123452 (assuming a base number of
123450, with a possible number range of 123450-123459). For a
single numbered line, enter the same number for both Primary and
Secondary entries.