en Installation instructions
Insert the cable plug and close the cable duct's lid.
5.
Insert the grease filters.
6.
To avoid causing damage, do not bend the grease
filters.
Swing the filter cover up and ensure that it engages.
7.
Removing the appliance
WARNING ‒ Risk of injury!
¡ The appliance is heavy.
To move the appliance, two people are required.
Use only suitable tools and equipment.
¡ Components inside the appliance may have sharp
edges.
Wear protective gloves.
¡ Risk of injury when opening and closing the hinges.
Keep your hands away from the hinges.
Disconnect the appliance from the power supply.
1.
Remove the grease filters.
2.
To avoid causing damage, do not bend the grease
filters.
Open the cable duct on the filter cover and loosen
3.
the cable.
Undo the screws on the hinges up to approx. 7 mm.
4.
Do not loosen the screws fully.
Unhook and remove the filter cover.
5.
22
Undo the screws on the top frame assembly using a
6.
screwdriver and remove the top frame assembly.
Loosen the screws on the side covers and remove
7.
the covers.