Superior GHC-6500 Homeowner's Care And Operation Instructions Manual

Hide thumbs Also See for GHC-6500:

Advertisement

RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
GHC-6500 SHOWN
WH Report No. J20046564
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
HOMEOWNER'S CARE AND
OPERATION INSTRUCTIONS
B-VENT
GHC/GRD-6500 SERIES
B-VENTED GAS FIREPLACES
P/N 725,030M REV. D 07/2004
MODELS
M
l i
v i l
t l o
M
o
e d
s l
G
H
- C
5 6
0 0
G
H
- C
5 6
0 0
G
R
- D
5 6
0 0
G
R
- D
5 6
0 0
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vaperurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où
vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appeflez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié
installer, agence de service ou le fournisseur de gaz.
E
e l
r t c
n o
c i
M
o
e d
s l
N
G
H
C
6 -
0 5
E 0
N
P
G
H
C
6 -
0 5
E 0
P
N
G
R
D
6 -
0 5
E 0
N
P
G
R
D
6 -
0 5
E 0
P
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GHC-6500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Superior GHC-6500

  • Page 1 B-VENTED GAS FIREPLACES P/N 725,030M REV. D 07/2004 MODELS v i l t l o r t c GHC-6500 SHOWN RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR WH Report No. J20046564 RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU...
  • Page 2: Table Of Contents

    WARNING: THESE FIREPLACES ARE VENTED DECORATIVE GAS APPLIANCES. In selecting this Superior B-vented gas appliance you have chosen the finest and most DO NOT BURN WOOD OR OTHER MATE- dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a RIAL IN THESE APPLIANCES.
  • Page 3: Operation/Care Of Your Appliance

    Figure 2 GRD-6500 APPLIANCE MENT WILL RESULT IN AN IMPROP- ERLY INSTALLED AND OPERATING AP- Control Compartment Access - GHC-6500 PLIANCE, VOIDING ITS WARRANTY. ANY Appliance operation must be controlled through Units a remotely located wall switch (factory-sup- CHANGE TO THIS APPLIANCE AND/OR plied).
  • Page 4: Combustion Air Controls

    MILLIVOLT GAS CONTROL VALVE stalled. Refer to Figure 7 for GHC-6500 series ELECTRONIC GAS CONTROL VALVE units and Figure 8 on page 5 for GRD-6500...
  • Page 5: Maintenance

    Actuator Manual Reset Limit Switch Lever Phillips Pan Head Screw #6-32 x ⁷⁄₃₂" (6 mm) Extension Bar Limit Combustion Air Control Lever and Switch Extension on GRD-6500 Series Units Screws Figure 8 Maintenance The appliance and venting system should be Fireplace Front Lintel Extention thoroughly inspected before initial use and at...
  • Page 6: Maintenance Schedule

    Maintenance Schedule Annually (Before the onset of the Burning Season) Maintenance Task Accomplishing Person Procedure Inspecting/Cleaning Burner, Logs Qualified Service Technician Inspect valve and ensure it is properly operat- and Controls ing. Check piping for leaks. Vacuum the control compartment, fireplace logs and burner area.
  • Page 7: Millivolt Appliance Checkout

    Logs and Rockwool (Glowing Embers) Placement WARNING: LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OFF. HANDLE ONLY WHEN LOGS ARE COOL. TURN OFF ALL ELECTRICITY TO THE APPLIANCE BEFORE YOU INSTALL GRATE AND LOGS.
  • Page 8 Carefully position and center the fiber logs onto the burner grate with the longer log in front and the shorter log all the way to the back of the fireplace. Place the four (4) smaller fiber logs across the two (2) lower logs in the manner illustrated (Figure 14) .
  • Page 9: Wiring Diagrams

    WIRING DIAGRAMS GHC-6500 GHC/GRD-6500 Robertshaw Ignition Control Equipped Robertshaw Ignition Control Equipped Wiring diagrams are provided here for refer- 1. If any of the original wire as supplied must be replaced, 1. If any of the original wire as supplied must be replaced, ence purposes only.
  • Page 10: Lighting Instructions - Millivolt

    LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted with a piezo •...
  • Page 11: Lighting Instructions - Electronic

    LIGHTING INSTRUCTIONS — ELECTRONIC FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions •...
  • Page 12 TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. POSSIBLE CAUSES CORRECTIVE ACTION SYMPTOM...
  • Page 13 TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM ote: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in the “ON” position. Important: “ON/OFF” switch must be “OFF” before performing continuity test. Adjust multimeter to the ohm setting when performing continuity tests. Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 14: Accessory Components

    Standard Remote Control System If the optional forced air kit, Model FAB-1600, (Model RCL) is to be used on the GHC-6500 Series appli- ances, refer to the installation instructions packed with the fan kit. The GHC-6500 Series The Model RCL (Standard) Remote Control...
  • Page 15: Replacement Parts List

    REPLACEMENT PARTS LIST MILLIVOLT SYSTEM , r a , r a , l e l l u , y r t e l , r a , t n , e l t f e , e l t f e c t i l l a GAS CONTROLS—...
  • Page 16 REPLACEMENT PARTS — MILLIVOLT GHC-6500 GRD-6500 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 17 REPLACEMENT PARTS LIST ELECTRONIC SYSTEM , r a , r a , l e l l u , y r t e l , r a , t n , e l t f e , e l t f e c t i l l a GAS CONTROLS—...
  • Page 18 REPLACEMENT PARTS — ELECTRONIC GHC-6500 GRD-6500 (REF) NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Table of Contents