Filling The Siphon With Water; Designating Heating Circuits - Only For Weather-Compensated Control Units - Viessmann Vitodens 200-W Installation And Service Instructions For Contractors

Wall mounted gas condensing boiler natural gas and lpg version
Table of Contents

Advertisement

Commissioning, inspection, maintenance
Venting the heating system
Activating the venting function
Weather-compensated control unit
Service menu
1. Press OK and
simultaneously for approx. 4 s.
å
2. "Service functions"
3. "Venting"
Venting function is enabled.
4. Ending venting function:
Press OK or
.
ä

Filling the siphon with water

Multi-boiler system:
Fill the siphon in the flue gas header with water as
well.
A
B
Fig. 19
1. Remove retaining clip
2. Fill siphon
with water.
B
Checking all connections on the heating water side and DHW side for leaks

Designating heating circuits - only for weather-compensated control units

In the delivered condition, heating circuits are designa-
ted "Heating circuit 1", "Heating circuit 2" and
"Heating circuit 3" (if installed).
If the system user prefers, heating circuits can be re-
designated to suit the specific system.
24
(cont.)
and siphon
.
A
B
Constant temperature control unit
Service menu
1. Press OK and
simultaneously for approx. 4 s.
å
2. Select "
5
" with
and confirm with OK.
Ú
"ON" flashes.
3. Activate the venting function with OK.
"EL on" is shown constantly.
4. Ending venting function:
Press
.
ä
3. Mount siphon
and secure with retaining clip
B
Note
Never twist the inlet hose during assembly. Route
the drain hose without any bends and with a con-
stant fall.