Viessmann Vitocell 100-W Installation And Service Instructions For Contractors page 8

Dhw cylinder

Advertisement

Preparing for installation
Connections
View from above
A
B
FEDC
Cylinder flow
A
Cylinder return
B
C
Inspection and cleaning aperture
Protective magnesium anode with earth cable
D
Connection, temperature sensor for thermometer
E
Siting information
!
Please note
The thermal insulation must not come into con-
tact with naked flames.
Exercise caution when welding and brazing.
!
Please note
To prevent material losses, install the DHW cyl-
inder in a room free from draughts and risk of
frost.
If the location is not frost free, drain the DHW
cylinder when it is not in use.
Use the adjustable feet to level the DHW cylinder.
8
Rear view
Sensor well for cylinder temperature controller
F
DHW
G
H
DHW circulation
Cold water
K
Note
Only use one or two of the adjustable feet to level the
DHW cylinder. At least one of the adjustable feet must
remain fully screwed in.
Fig. 2
Never extend the adjustable feet beyond a total length
of 35 mm.
G
H
K
≤35