ProxySG 9000 Series FIPS Compliance Guide: Tamper Evident Panel and Label Installation For Compliance Model Number 9000...
Page 2
Blue Coat may make changes to this document, or to the products described herein, at any time without notice. Blue Coat makes no commitment to update this document.
This document describes how to install louvered shutters and apply serialized labels over various apertures and joints. These shutters and labels secure and tamper-proof the Blue Coat® SG9000 series appliances. Applying these materials is one of the tasks involved to make your network environment Federal Information Processing Standards (FIPS) compliant.
The supplied labels are serialized. Manually recording label serial numbers as you apply labels to Blue Coat appliances is optional. If you are asked to perform this task, Blue Coat recommends creating a matrix that associates Blue Coat appliances with a physical location, then record each serial number as you add labels.
Step 3: Repeat if necessary. Before You Begin If the Blue Coat appliance is already rack-mounted and operating, Blue Coat recommends powering it down, removing the system from the rack, and creating a workplace with ample room to maneuver around the unit.
Page 6
SG9000 Tamper Evident Panel and Label Installation Procedure: Installing the Louvered Shutters The FIPS compliance louvered shutters are designed to prevent unauthorized access to key system components by shielding the rear ventilation outlets. The kit includes one large shutter, which covers the primary ventilation outlet and a smaller shutter, which covers the secondary outlet.
Page 7
SG9000 Tamper Evident Panel and Label Installation Step 2: Align the small louvered shutters against the mounting points shown below and secure with two flat-head screws. Step 2 Flat-Head Screw...
Page 8
SG9000 Tamper Evident Panel and Label Installation Procedure: Applying the High-Security Labels The FIPS compliant labels are applied over key areas of the chassis to provide tamper- evident security. If the labels are removed after being affixed to a surface, the image self-destructs and leaves tamper-evident text on the label.
Page 9
SG9000 Tamper Evident Panel and Label Installation Step 3: Apply one short label across the large louvered shutter and over the chassis. Be sure that the label covers both parts in equal amounts. Step 3 Short Label...
Page 10
SG9000 Tamper Evident Panel and Label Installation Step 4: Apply one short label across and over the small louvered shutter mounting tab.Make sure it covers the entire mounting tab and extends over the right edge of the appliance. Step 5: Apply one short label across the center of the small louvered shutter. Make sure it covers both the small louvered shutter and extends over the right edge of the appliance.
Page 11
SG9000 Tamper Evident Panel and Label Installation Step 7: Apply one short label across the edge of the middle panel as to secure the panel to the chassis. The label should be placed approximately three-quarters of an inch beyond the release tab. Step 7 Short Label Step 8: Rack mount the appliance.
Page 12
SG9000 Tamper Evident Panel and Label Installation Step 12: Close the bezel. Step 13: Apply two short labels across the chassis and bezel to prevent unauthorized access to the front panel and hard disk carriers. Each label should be placed on the opposite ends of the appliance, as shown below.