MODEL NO.
HEAT INPUT RATE IN BTU/HR
HEATING CAPACITY IN BTU/HR
HEIGHT OF CASING
WIDTH OF CASING
DEPTH OF CASING
WARM AIR OUTLET
RETURN AIR INLET
DIA. OF FLUE OUTLET
FLOOR-CENTER OF FLUE
FLOWRATE from .2" & .5" w.c.
EXTERNAL STATIC PRESSURE
@2 TON SWITCH SELECTION (CFM)
@2-1/2 TON SWITCH SELECTION (CFM)
@3 SWITCH SELECTION (CFM)
@3-1/2 TON SWITCH SELECTION (CFM)
@70deg SWITCH SELECTION (CFM)
APPROX TEMPERATURE RISE (°F)
BLOWER MOTOR HP
NOZZLE SIZE
NOZZLE SPRAY ANGLE PATTERN
LARGEST RECOMMENDED
AIR CONDITIONER
SIZE OF FILTERS
NOTES:
1.
Heating capacity based on annual fuel utilization efficiency rated by manufacturer.
2.
On all outlet and inlet dimensions, the first dimension is width.
3.
To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is
required.
7. Electrical characteristics at 115 volts, 60 Hz., 1 phase (less than 15 amps, for all models).
8. All specifications are subject to change without notice.
OC2-56
OC5-85
70,000
106,250
56,000
85,000
57-1/2"
56"
19"
24"
27"
33"
17 x 17
16 x 20
17 x 17
22 x 20
5"
6"
TOP
TOP
COOLING
COOLING
800
800
1000
1000
1200
1200
1400
1400
HEATING
HEATING
737
1134
70
70
1/2
1/2
.55
.75
80º Hollow
80º Hollow
3.5 Ton
3.5 Ton
17" x 10"
20" x 12"
3