KSR5317
Installation Sheet
Read these instructions before commencing installation. Please give these instructions to the owner/occupier after
installation to retain for future reference/maintainence.
IP65
240V~50Hz 50W 4000K LED
These fittings are Class II and should not be Earthed
Important Information
It is recommended that these luminaires are installed and fitted by a qualified electrician
ensuring the installation complies with current IEE wiring regulations & local building
control. These products are designed for connection to a 240V~50Hz supply.
Any faulty, broken or damaged luminaires should be replaced immediately.
KSR will not accept responsibility for any claims arising from a poor installation.
Please Note: The limited warranty shall be deemed null and void in the following circumstances: Failure by the
installer, end user or any third party to exercise caution to protect any covered product or part from outside damage,
humidity conditions, fluctuations in the electrical system or physical abuse as well as failure related to workmanship in
the installation of the products or parts.
Important User Advice
Always safely isolate the mains supply before installing/servicing.
Please note this luminaire is Non Dimmable.
General maintenance and cleaning should be performed at least quarterly.
Clean product outer using a damp cloth, the glass can be cleaned with hot soapy water, dried and buffed to a shine.
Greasing screws and nuts with a suitable waterproof repellent will ensure the product gives you a long lasting trouble
free life/finish.
At the end of life the luminaire is classed as WEEE under directive 2014/30/EU and should be disposed of in
accordance with local legislation.
Installation Procedure
Ensure mains supply is safely isolated. Locate a suitable location for the luminaire, use the mounting bracket as a
template to drill fixing holes. Secure the bracket into position using suitable fixings. Prepare wiring, using suitable
cable for the application. When securing this product to a wall, please remember to allow enough slack cable to tilt the
luminaire to its final resting position. Never allow the mains cable to become strained.
Terminate the wiring as per Fig.1 using a suitable IP rated connector/junction box.
Adjust the angle of tilt to the required position and tighten bolts to a maximum torque of 7.3Nm.
Position the PIR in the direction required and tighten the screw on the knuckle ensuring it is tight, always re-check
after repositioning. If this is not tightened the water ingress protection will be reduced and can cause premature failure.
Turn mains supply on and test luminaire.
Pass on these instruction sheets to the owner/occupier.
To adjust the settings you require on the PIR see overleaf.
Fig.1
Wiring Details
Luminaire
Mains Supply
Brown (L)
Brown - Live
Blue (N)
Blue - Neutral
20.07.2021MAC
KSR Lighting Ltd, Unit E Hazleton Interchange, Lakesmere Road, Horndean, Hampshire, PO8 9JU
Siena CL
LED Floodlight with PIR
Available finish: Anthracite
247mm
230mm
Lamp Details
Lamp: 50W - 4000K
Lumen Output: 5255 lumens
CRI: >Ra82
°
Beam Angle: 107
The light source of this luminaire is not replaceable;
when the light source reaches its end of life the whole
luminaire shall be replaced
This product contains a light source of energy efficiency class E
KSR Lighting Aftersales: 023 92 674343
E-mail: aftersales@ksrlighting.com
28mm
52mm
Drg No. KSR5317-IS-A