Memory Settings

MEMORY

REC

Parameter
Value
Specifies the overdubbing method.
OVERDUB
DUB MODE
REPLACE
Specifies the order in which record/playback/overdubbing are switched when you press the [REC/PLAY] switch.
REC ACTION
REC->DUB
REC->PLAY
With tracks for which LOOP.S (p. 3) is "ON, " under any of the conditions listed below, your timing will be corrected
(Loop Quantize) based on the tempo and time signature of the rhythm, even if the timing at which you press a button is
slightly inaccurate.
5 If the rhythm is on
5 If there is an already-recorded track whose LOOP.S is turned on
5 If the MIDI Sync is on
QUANTIZE
* The QUANTIZE setting applies only during recording. It is ignored during overdubbing or playback.
* When you stop recording, it is quantized to match the measure length of the previously-recorded track (LOOP.S: ON) or
rhythm.
OFF
MEASURE
"AUTO REC" (auto record) starts recording when there is audio input from your guitar performance or the mic.
OFF
AUTO REC
ON
A.REC SENS
*1 1–50–100
Specifies the input to which AUTO REC applies.
ALL
MIC IN
A.REC SRC
*1
INST
INST-A
INST-B
Specifies the length to which LOOP.S (p. 3) aligns the beginnings of the material for loop sync.
LOOP LENGTH
AUTO
1–25362
(*1) This is valid when AUTO REC is "ON. "
4
Explanation
(Bold: default)
The new performance is layered onto the prerecorded tracks.
If overdubbing is repeated, the next performance is layered on top of the previous material,
allowing you to create an ensemble in a single track.
Tracks with existing recordings are overwritten as new tracks are recorded over them.
Overwriting takes places while the previously recorded tracks are played back, allowing you
to achieve a kind of delay effect similar to that obtained from an effects processor.
Operation will switch in the order of Recording 0 Overdubbing 0 Playback.
Operation will switch in the order of Recording 0 Playback 0 Overdubbing.
Recording begins the instant you perform the operation.
When you stop recording, it is quantized to match the measure.
Quantize to the measure start location for recording.
Recording will begin the instant you press the [REC/PLAY] switch.
When you press the [REC/PLAY] switch, the REC/PLAY indicator will blink rapidly, and the
RC-500 will enter recording-standby mode.
When you begin playing, the REC/PLAY indicator will light and recording will start.
Specifies the input sensitivity at which auto record starts. Recording will start when the
input from the guitar or mic exceeds the specified sensitivity.
MIC IN connector, INST IN jacks (A/MONO, B)
MIC IN connector
INST IN jacks (A/MONO, B)
INST IN A/MONO jack
INST IN B jack
The length of the first-recorded phrase will be the LOOP LENGTH.
Manually specifies the number of measures that will be looped.