Choosing the Right Power Cord
Long or thin cords can drain the power provided to an electrical device by the generator. When
using such cords, allow for a slightly higher rated wattage requirement for the electrical device. See
the table below for recommended cords based on the power requirement of the electrical device.
DEVICE REQUIREMENTS
AMPS
WATTS (120/240V)
5
10
15
20
25
30
40
50
*NR = NOT RECOMMENDED
600/1200
1200/2400
1800/3600
2400/4800
3000/6000
3600/7200
4800/9600
6000/12000
WIRE GAUGE BY LENGTH (ft.)
10
25
18
16
16
14
14
14
12
12
12
10
10
10
8
8
6
6
*Gauge based on twisted copper wire
50
100
14
12
12
12
12
12
12
10
10
10
10
8
6
6
6
NR
150
10
10
10
10
8
NR
NR
NR
39