Busbar protection REB670
Version 2.2
Binary input/output modules
For pulse counting, for example kWh metering, the BIM with enhanced pulse counting capabilities must be used.
Note: 1BIM and 1 BOM included in A20, A31 and B20. 2 BIM and 1 BOM included in B21 and B31
Slot position (front view/rear view)
1/2 case with 1 TRM
3/4 case with 1 TRM
3/4 case with 2 TRM
1/1 case with 2 TRM
Compression terminals
No board in slot
Binary output module 24 output
relays (BOM)
BIM 16 inputs, RL24, 24-30VDC, 50
mA
BIM 16 inputs, RL48, 48-60VDC,
50mA
BIM 16 inputs, RL110, 110-125VDC,
50mA
BIM 16 inputs, RL220, 220-250VDC,
50mA
BIM 16 inputs, RL220, 220-250VDC,
120mA
BIM 16 inputs, RL24, 24-30VDC,
50mA, enhanced pulse counting
BIM 16 inputs, RL48, 48-60VDC,
50mA, enhanced pulse counting
BIM 16 inputs, RL110, 110-125VDC,
50mA, enhanced pulse counting
BIM 16 inputs, RL220, 220-250VDC,
50mA, enhanced pulse counting
IOM 8 inputs, RL 24-30 VDC, 50mA,
10+2 output relays
IOM 8 inputs, RL 48-60 VDC, 50mA,
10+2 output relays
IOM 8 inputs, RL 110-125 VDC,
50mA, 10+2 output relays
IOM 8 inputs, RL 220-250 VDC,
50mA, 10+2 output relays
IOM 8 inputs, RL 220-250 VDC,
110mA, 10+2 output relays
IOM with MOV 8 inputs, RL 24-30
VDC, 50mA, 10+2 output relays
IOM with MOV 8 inputs, RL 48-60
VDC, 50mA, 10+2 output relays
IOM with MOV 8 inputs, RL 110-125
VDC, 50mA, 10+2 output relays
IOM with MOV 8 inputs, RL 220-250
VDC, 50mA, 10+2 output relays
mA input module MIM 6 channels
SOM static output module, 6 heavy
duty static outputs, 250 VDC + 6
output relays
1)
Max 3 positions in 1/2 rack, 8 in 3/4 rack with 1 TRM, 5 in 3/4 rack with 2 TRM and 11 in 1/1 rack with 2 TRM
2)
Only for A20/B20
3)
Only for A31/B21/B31
4)
Maximum 4 BOM+SOM boards. P5 not in B21/B31.
5)
One BOM required in postion P4.
6)
1 BIM required in position P3. 2 BIMs required in position P3 and P5 for B21 and B31.
7)
P5 not in B21/B31
8)
SOM must not to be placed in the position nearest to NUM: 1/2 case slot P5, 3/4 case 1 TRM slot P10, 3/4 case 2 TRM slot P7, 1/1 case 2 TRM slot P13, 1/1 case, 1 TRM slot P16.
Hitachi Power Grids
Ordering no
C
1MRK000614-AB
1MRK000508-DD
B1
1MRK000508-AD
C1
1MRK000508-BD
D1
1MRK000508-CD
E1
1MRK000508-CE
E2
1MRK000508-HA
1MRK000508-EA
1MRK000508-FA
1MRK000508-GA
1MRK000173-GD
1MRK000173-AE
1MRK000173-BE
1MRK000173-CE
1MRK000173-CF
1MRK000173-GC
1MRK000173-AD
1MRK000173-BD
1MRK000173-CD
1MRK000284-AB
1MRK002614-CA
Selection for
C
position #10
© 2017 - 2021 Hitachi Power Grids. All rights reserved
#10
X
X
X
X
X
A
A
A
A
A
A
B1
B1
B1
B1
B1
C1
C1
C1
C1
C1
D1
D1
D1
D1
D1
E1
E1
E1
E1
E1
E2
E2
E2
E2
E2
F
F
F
F
F
G
G
G
G
G
H
H
H
H
H
K
K
K
K
K
L1
L1
L1
L1
L1
M1
M1
M1
M1
M1
N1
N1
N1
N1
N1
P1
P1
P1
P1
P1
P2
P2
P2
P2
P2
U
U
U
U
U
V
V
V
V
V
W
W
W
W
W
Y
Y
Y
Y
Y
R
R
R
R
R
T2
T2
T2
T2
T2
1MRK 505 373-BEN P
Notes and rules
1)
2)
2)
3)
3)
X
X
X
X
A
A
A
A
4)
5)
,
B1
B1
B1
B1
6)
C1
C1
C1
C1
D1
D1
D1
D1
E1
E1
E1
E1
E2
E2
E2
E2
F
F
F
F
7)
G
G
G
G
H
H
H
H
K
K
K
K
L1
L1
L1
L1
M1
M1
M1
M1
N1
N1
N1
N1
P1
P1
P1
P1
P2
P2
P2
P2
U
U
U
U
V
V
V
V
W
W
W
W
Y
Y
Y
Y
R
R
R
R
T2
T2
T2
8)
7)
,
133

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reb670

Table of Contents