PCB Piezotronics IMI SENSORS 691M157 Installation And Operating Manual

PCB Piezotronics IMI SENSORS 691M157 Installation And Operating Manual

Termination box

Advertisement

Quick Links

Model 691M157
TERMINATION BOX
Installation and Operating Manual
For assistance with the operation of this product,
contact the PCB Piezotronics, Inc.
Toll-free: 800-959-4464
24-hour SensorLine: 716-684-0001
Fax: 716-684-3823
E-mail: imi@pcb.com
Web: www.imi-sensors.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IMI SENSORS 691M157 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PCB Piezotronics IMI SENSORS 691M157

  • Page 1 Model 691M157 TERMINATION BOX Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour SensorLine: 716-684-0001 Fax: 716-684-3823 E-mail: imi@pcb.com Web: www.imi-sensors.com...
  • Page 2  Assistance is needed to safely operate equipment  PCB Piezotronics is an ISO-9001 certified company whose Damage is visible or suspected  calibration services are accredited by A2LA to ISO/IEC Equipment fails or malfunctions 17025, with full traceability to SI through N.I.S.T.
  • Page 3 CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
  • Page 4 PCB工业监视和测量设备 - 中国RoHS2公布表 PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 有害物质 镉 汞 铅 (Pb) 六价铬 (Cr(VI)) 多溴联苯 (PBB) 多溴二苯醚 (PBDE) 部件名称 (Hg) (Cd) 住房 PCB板 电气连接器 压电晶体 环氧 铁氟龙 电子 厚膜基板 电线 电缆 塑料 焊接...
  • Page 5 Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
  • Page 6 INDUSTRIAL MONITORING INSTRUMENTATION DIVISION Models 691M156 and 691M157 Termination Boxes for Triaxial ICP® Accelerometers Operating Guide with Enclosed Warranty Information 3425 Walden Avenue, Depew, New York 14043-2495 Phone (716) 684-0003 Fax (716) 684-3823 Toll Free Line 1-800-959-4IMI MANUAL NUMBER: 66865 MANUAL REVISION: NR ECO 46608...
  • Page 7: Table Of Contents

    INDUSTRIAL MONITORING INSTRUMENTATION DIVISION Table of Contents Introduction ........................Page 3 Installation ........................Page 3 Wiring .......................... Pages 4-5 Figure 1 – Typical Input Channel Wiring ..............Pages 4-5 Calibration ........................Page 5 ESD Warning Information ....................Page 6 Warranty/Servicing Warranty, Service &...
  • Page 8: Introduction

    INDUSTRIAL MONITORING INSTRUMENTATION DIVISION Introduction The termination boxes for triaxial ICP® accelerometers (Models 691M156 and 691M157) provide terminal strip inputs with the convenience of 4-pin bayonet connector outputs. They are used in conjunction with commercially available data collectors and analyzers. A few specifications are listed below for easy reference. Specifications 691M56 ................
  • Page 9: Wiring

    INDUSTRIAL MONITORING INSTRUMENTATION DIVISION Wiring Remove outer cover of the enclosure by loosening the four screws located in each corner of the front panel. Strip cables back approximately 1/8” to 3/16”. Note the length of the conductor as not to short any neighboring cables. Feed cables through cable grips.
  • Page 10: Calibration

    INDUSTRIAL MONITORING INSTRUMENTATION DIVISION Figure 1 – Typical Input Channel Wiring (Continued) Calibration The termination boxes do not need any calibration. If there are any questions concerning these products, please contact the factory. PAGE 5...
  • Page 11 Warning 2 – ESD Sensitivity This equipment is designed with user safety in mind; however, the protection provided by the equipment may be impaired if the equipment is used in a manner not specified by PCB Piezotronics, Inc. Caution 1 – ESD Sensitivity Cables can kill your equipment.
  • Page 12 INDUSTRIAL MONITORING INSTRUMENTATION DIVISION Warranty IMI instrumentation is warranted against defective material and workmanship for 1 year unless otherwise expressly specified. Damage to instruments caused by incorrect power or misapplication, is not covered by warranty. If there are any questions regarding power, intended application, or general usage, please consult with your local sales contact or distributor.
  • Page 13: Customer Service

    Customer Service IMI, a division of PCB Piezotronics, guarantees Total Customer Satisfaction. If, at any time, for any reason, you are not completely satisfied with any IMI product, IMI will repair, replace, or exchange it at no charge. You may also choose, within the warranty period, to have your purchase price refunded.
  • Page 14 Model Number Revision: NR TERMINATION BOX 691M157 ECN #: 46608 Performance ENGLISH OPTIONAL VERSIONS Channels(Tri-Ax) Optional versions have identical specifications and accessories as listed for the standard model Environmental except where noted below. More than one option may be used. Enclosure Rating Nema 4X IP66...
  • Page 15 PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. RELEASED TO DRAFTING 46608 2.95 [74.9] 1.48 [37.5] CABLE GRIP 1.06 [27.0]...
  • Page 16 INDUSTRIAL MONITORING INSTRUMENTATION DIVISION Models 691M156 and 691M157 Termination Boxes for Triaxial ICP® Accelerometers Operating Guide with Enclosed Warranty Information 3425 Walden Avenue, Depew, New York 14043-2495 Phone (716) 684-0003 Fax (716) 684-3823 Toll Free Line 1-800-959-4IMI MANUAL NUMBER: 66865 MANUAL REVISION: NR ECO 46608...
  • Page 17 INDUSTRIAL MONITORING INSTRUMENTATION DIVISION Table of Contents Introduction ........................Page 3 Installation ........................Page 3 Wiring .......................... Pages 4-5 Figure 1 – Typical Input Channel Wiring ..............Pages 4-5 Calibration ........................Page 5 ESD Warning Information ....................Page 6 Warranty/Servicing Warranty, Service &...
  • Page 18: Introduction

    INDUSTRIAL MONITORING INSTRUMENTATION DIVISION Introduction The termination boxes for triaxial ICP® accelerometers (Models 691M156 and 691M157) provide terminal strip inputs with the convenience of 4-pin bayonet connector outputs. They are used in conjunction with commercially available data collectors and analyzers. A few specifications are listed below for easy reference. Specifications 691M56 ................
  • Page 19: Wiring

    INDUSTRIAL MONITORING INSTRUMENTATION DIVISION Wiring Remove outer cover of the enclosure by loosening the four screws located in each corner of the front panel. Strip cables back approximately 1/8” to 3/16”. Note the length of the conductor as not to short any neighboring cables. Feed cables through cable grips.
  • Page 20: Calibration

    INDUSTRIAL MONITORING INSTRUMENTATION DIVISION Figure 1 – Typical Input Channel Wiring (Continued) Calibration The termination boxes do not need any calibration. If there are any questions concerning these products, please contact the factory. PAGE 5...
  • Page 21 Warning 2 – ESD Sensitivity This equipment is designed with user safety in mind; however, the protection provided by the equipment may be impaired if the equipment is used in a manner not specified by PCB Piezotronics, Inc. Caution 1 – ESD Sensitivity Cables can kill your equipment.
  • Page 22 INDUSTRIAL MONITORING INSTRUMENTATION DIVISION Warranty IMI instrumentation is warranted against defective material and workmanship for 1 year unless otherwise expressly specified. Damage to instruments caused by incorrect power or misapplication, is not covered by warranty. If there are any questions regarding power, intended application, or general usage, please consult with your local sales contact or distributor.
  • Page 23: Customer Service

    Customer Service IMI, a division of PCB Piezotronics, guarantees Total Customer Satisfaction. If, at any time, for any reason, you are not completely satisfied with any IMI product, IMI will repair, replace, or exchange it at no charge. You may also choose, within the warranty period, to have your purchase price refunded.

Table of Contents