Download Print this page
PCB Piezotronics IMI SENSORS 691A51/01 Installation And Operating Manual

PCB Piezotronics IMI SENSORS 691A51/01 Installation And Operating Manual

Bnc termination box
Hide thumbs Also See for IMI SENSORS 691A51/01:

Advertisement

Quick Links

Model 691A51/01
BNC Termination Box
Installation and Operating Manual
For assistance with the operation of this product,
contact PCB Piezotronics, Inc.
Toll-free: 800-959-4464
24-hour SensorLine: 716-684-0001
Fax: 716-684-3823
E-mail: imi@pcb.com
Web: www.imi-sensors.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the IMI SENSORS 691A51/01 and is the answer not in the manual?

Questions and answers

Summary of Contents for PCB Piezotronics IMI SENSORS 691A51/01

  • Page 1 Model 691A51/01 BNC Termination Box Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour SensorLine: 716-684-0001 Fax: 716-684-3823 E-mail: imi@pcb.com Web: www.imi-sensors.com...
  • Page 2  Assistance is needed to safely operate equipment  PCB Piezotronics is an ISO-9001 certified company whose Damage is visible or suspected  calibration services are accredited by A2LA to ISO/IEC Equipment fails or malfunctions 17025, with full traceability to SI through N.I.S.T.
  • Page 3 CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
  • Page 4 PCB工业监视和测量设备 - 中国RoHS2公布表 PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 有害物质 镉 汞 铅 (Pb) 六价铬 (Cr(VI)) 多溴联苯 (PBB) 多溴二苯醚 (PBDE) 部件名称 (Hg) (Cd) 住房 PCB板 电气连接器 压电晶体 环氧 铁氟龙 电子 厚膜基板 电线 电缆 塑料 焊接...
  • Page 5 Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
  • Page 6 INDUSTRIAL MONITORING INSTRUMENTATION DIVISION The Model 691A51 Series Vibration Termination Boxes Operating Guide with Enclosed Warranty Information 3425 Walden Avenue, Depew, New York 14043-2495 Phone (716) 684-0003 Fax (716) 684-3823 Toll Free Line 1-800-959-4IMI MANUAL NUMBER: 18424 MANUAL REVISION: NR...
  • Page 7: Table Of Contents

    INDUSTRIAL MONITORING INSTRUMENTATION DIVISION table of contents Introduction........................page 3 Installation ........................page 3 Wiring .......................... pages 4-5 Figure 1 – Typical Input Channel Wiring ..............pages 4-5 Calibration ........................page 5 ESD Warning Information....................page 6 warranty/servicing Warranty, Service & Return Procedure ................page 7 Customer Service......................
  • Page 8: Introduction

    INDUSTRIAL MONITORING INSTRUMENTATION DIVISION introduction The Model 691A51 Series Vibration Termination Boxes provide terminal strip input with the convenience of BNC outputs. They are used in conjunction with commercially available data collectors and analyzers. A few specifications are listed below for easy reference. 689A51 Specifications 691A51/01 ...............
  • Page 9: Wiring

    INDUSTRIAL MONITORING INSTRUMENTATION DIVISION wiring Remove outer cover of the enclosure by loosening the four screws located on the front panel. Strip cable approximately 1/8” to 3/16” (Note the length of the conductor as not to short any neighboring cables). Feed cables through cable grips.
  • Page 10: Calibration

    INDUSTRIAL MONITORING INSTRUMENTATION DIVISION figure 1 – typical input channel wiring continued . . . positive conductor push down using a screwdriver shield conductor negative conductor sensor input wire calibration The 691A51 series does not need any calibration. If there are any questions concerning these products, please contact the factory.
  • Page 11: Esd Warning Information

    2 – ESD sensitivity This equipment is designed with user safety in mind; however, the protection provided by the equipment may be impaired if the equipment is used in a manner not specified by PCB Piezotronics, Inc. caution 1 – ESD sensitivity Cables can kill your equipment.
  • Page 12: Warranty, Service & Return Procedure

    INDUSTRIAL MONITORING INSTRUMENTATION DIVISION warranty IMI instrumentation is warranted against defective material and workmanship for 1 year unless otherwise expressly specified. Damage to instruments caused by incorrect power or misapplication, is not covered by warranty. If there are any questions regarding power, intended application, or general usage, please consult with your local sales contact or distributor.
  • Page 13: Customer Service

    IMI, a division of PCB Piezotronics, guarantees Total Customer Satisfaction. If, at any time, for any reason, you are not completely satisfied with any IMI product, IMI will repair, replace, or exchange it at no charge. You may also choose, within the warranty period, to have your purchase price refunded.
  • Page 14 Model Number Revision: D BNC TERMINATION BOX 691A51/01 ECN #: 47498 Performance ENGLISH OPTIONAL VERSIONS Channels Optional versions have identical specifications and accessories as listed for the standard model Environmental except where noted below. More than one option may be used. Temperature Range -15 to 185 °F -26 to 85...