Download Print this page

Daikin RKC09NV2S Service Manual Removal Procedure page 7

1.5/2.0/2.5/3.5 kw class 9000/12000 btu/h class

Advertisement

Si001416E
Step
3
Release the fan motor
lead wire from the 2
grooves and the 2
hooks.
4
Remove the screw and
remove the fan motor
fixing frame.
5
Unfasten the 2 hooks
on the motor fixing
frame and release the
fan motor lead wire.
6
Remove the 3 screws
and remove the fan
motor.
Removal Procedure
Procedure
Groove
Fan motor fixing frame
Fan motor lead wire
Hook
Fan motor
When reassembling, pass
Hook
the fan motor lead wire as
shown below.
(R21293)
When reassembling, fit the 2
lower hooks into the bottom
frame.
(R21294)
(R21295)
Screw size: M4 × 16
(R21296)
Outdoor Fan / Fan Motor
Points
Fan motor lead wire
(R21320)
(R10460)
5