MAINTENANCE PROCEDURE
•
It is dangerous if the work equipment moves by mistake when the tooth is being replaced.
Set the work equipment in a stable condition, set the lock lever securely to LOCK position, and stop
the engine.
•
Broken pieces may fly during the replacement work, so always wear the protective equipment such
as protective eyeglasses and gloves.
•
If the tooth pin cannot be removed by this method, ask your Komatsu distributor to have the re-
placement performed for safety.
•
As the pin is driven out with strong force, it is dangerous that the pin may fly out. Check that there
is no people around the machine.
•
Provide a socket wrench of 14 mm width.
1.
Place a block (3) under the bucket so that the pin (1) is
driven out, and stop the engine.
2.
Turn the staring switch key to ON position within 15 sec-
onds after stopping the engine, and move each control lev-
er (for work equipment and travel) to the full stroke in all di-
rections in order to release the internal pressure.
3.
Check that the work equipment is in a stable condition,
then set the lock lever to LOCK position (L).
4.
Fit the socket wrench to the head of the pin (1), and turn it
counterclockwise by 90 ° to unlock the pin.
4-26
k
k
WARNING