Universal Security Instruments Sensing Plus AMI3051S Instructions Manual page 9

Multi-criteria single station smoke alarm
Table of Contents

Advertisement

ALARM AUDIBLE & VISUAL SIGNALS
CONDITION
New - Out
of Package
DC Power is
Present
Test/Silence
Button Has
2 second pause,
Been Pressed
Originating
2 second pause,
Smoke Alarm
Nuisance
Alarm
2 second pause,
Alarm has
Sensed Smoke
2 second pause,
Alarm has
Previously
Sensed Smoke
Alarm needs to
be reset due
to varying
conditions/
previous alarms
Low Battery
approx every
60 seconds
Product
End-of-Service
approx every
Life Notification
60 seconds
(Alarm
Calibration)
Warning
Alarm Reset - Press and Hold the Test/Silence button for approximately 10 seconds and release. This will clear the Silence
Feature and Alarm Origination.
THIS PRODUCT CONFORMS TO UL STANDARD 217 8TH EDITION FOR SAFETY
Quick Reference Guide Model AMI3051S
HORN
RED LED
Silent
Silent
Blinks On once
approx every
2 minutes
3 beeps,
Blinks On in sync
with Horn
3 Beeps,
Blinks On in sync
with Horn
Repeat
3 Beeps,
Blinks On in sync
with Horn
Repeat
3 Beeps,
Blinks On in sync
with Horn
Repeat
Silent
Blinks On once
(alarmed
approx every
previously)
2 minutes
(normal operation
mode) or Blinks On
once approx every
10 seconds
(silence mode)
Silent
Blinks On once
approx every
2 minutes
(normal operation
mode) or Blinks On
once approx every
10 seconds
(silence mode)
1 chirp
Blinks On once
approx every
2 minutes
2 chirps
Blinks On once
approx every
2 minutes
Silent
3 Blinks approx.
every 2 minutes
Off
To activate the alarm, remove the pull tab. The alarm will sound
one long beep to confirm it is powered up. Press the Test/Silence
button. Test the alarm following installation and weekly thereafter.
The built-in test switch accurately tests the alarm operation as
required by ANSI/UL217 Standards for Safety. If, at any time,
you test the alarm and it does not perform as described, replace
it immediately.
The alarm is operating properly.
The alarm is operating properly.
If hazard is identified, please take all precautions if an alarm
sounds by calling an Emergency Service and getting out of
the home.
If there is no hazard present, verify the alarm is mounted
in the correct location (see User's Manual, "AVOID THESE
LOCATIONS" section). Reset alarm as instructed below.
Silence Feature is activated by pressing and releasing the Test/
Silence button on the initiating alarm while in alarm condition.
Silence mode will last for approx 10 minutes with the red LED
blinking once approx. every 10 seconds.
QUICK FIND
allow you to locate the originating alarm (once the alarms have
stopped sounding). To initiate QUICK FIND
Silence button. After releasing the button, the originating alarm
will continue to sound for approx 60 seconds. It is necessary to
test each alarm to determine the originating alarm.
To reset the alarm, hold the Test/Silence button for approx 10
seconds and release. This will clear Alarm Origination. Reset
alarm after every alarm event.
Deactivate alarm (see User's Manual "ALARM DEACTIVATION"
section). Replace alarm immediately.
Deactivate alarm (see "ALARM DEACTIVATION" section in
User's Manual). Replace alarm immediately.
Clean Alarm. See MAINTENANCE instructions on the following
page. Reset the alarm. See Reset Instructions below. If this
does not clear the problem, replace alarm. Deactivate Alarm.
See User's Manual "ALARM DEACTIVATION" section. Replace
alarm immediately.
Page 9
RECOMMENDATION
Alarm Origination - The QUICK FIND
®
feature will
®
, press the Test/
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sensing Plus AMI3051S and is the answer not in the manual?

Table of Contents