Page 1
1Top cover ENGLISH OPERATOR'S MANUAL PB-2350 WARNING READ THE INSTRUCTIONS CAREFULLY AND FOLLOW THE RULES FOR SAFE OPERATION. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY.
Page 2
Always keep your manual in a place where it is readily accessible. If you have lost your manual or it is damaged and no longer readable, please purchase a new one from your ECHO DEALER.
Contents For safe use of your product....................4 Warning notices ......................4 Other indicators ......................4 Symbols ......................... 4 Location in which the safety decal is attached............... 6 Handling fuel........................7 Handling the engine....................... 8 Handling the product ..................... 9 Packing list........................
For safe use of your product For safe use of your product Be careful to read this section before using your product. The precautions described in this section contain important safety information. Please observe them carefully. You must also read the precautions that appear in the body of the manual itself. Text following a [diamond mark] mark describes the potential consequences of failing to observe the precaution.
Page 5
For safe use of your product Symbol form/shape Symbol description/applica- Symbol form/shape Symbol description/applica- tion tion Choke Control Do not use the product in plac- "Cold Start" es with poor ventilation Position (Choke Closed) Choke Control "Run" Beware of fire Position (Choke Open) Beware of electric shocks...
If the decal becomes unreadable due to wear and tear or damage, or peels off and is lost, please purchase a replacement decal from your ECHO DEALER and attach it in the location shown in the illustrations below. Ensure that the decal is readable at all times.
If you do find fuel leaks or discharges, stop using the Tighten the fuel tank cap securely after refuelling. product immediately and contact your ECHO DEALER Fuel spills can cause fire and burns when ignited. to have it repaired.
You could burn yourself. once the engine starts. Do not use the product if there Remove the spark plug cap before performing checks are abnormal vibrations or sounds. Contact your ECHO and maintenance DEALER to have it repaired.
For safe use of your product Handling the product General precautions WARNING Operator's manual Loaning or assigning your product Be careful to read the operator's manual When loaning your product to another party, ensure properly before using your product in or- that the person borrowing the product receives the op- der to ensure correct operation.
Page 10
For safe use of your product Precautions for use WARNING Users of the product Turn off the engine when moving around The product should not be used by: When moving around in the situations described below, people who are tired turn off the engine and move with the product shouldered.
Page 11
(RSI). Contact your ECHO DEALER for repair. To reduce the risk of RSI, do the following: Continuing to use parts when they are damaged could lead ...
Packing list The following parts are packed separately in the packing box. When you have unpacked the box, please check the parts that it contains. Contact your ECHO DEALER if anything is missing or broken. Number Part name...
Description Description 1. Blower pipes Exclusive positive locking system. 8. Choke Choke is located on top of the air cleaner. Move 2. Air cleaner Contains replaceable air filter element. choke lever to position to close choke for cold start- 3. Starter handle Pull recoil handle slowly until recoil starter ing.
Before you start Before you start Assembly WARNING Read the operator's manual carefully to ensure that you assemble the product correctly. Never perform maintenance or assembly procedures with engine running. Using a product that has been incorrectly assembled could lead to an accident or serious injury. Install vacuum tube Turn screw anticlockwise until hinged housing cover is free to open for vacuum tube installation.
Page 15
Before you start Tighten screw securely. 1. Screw Place debris bag opening over flared end of vacuum elbow, and cinch debris bag securely with velcro strap (C). 1. Debris bag Install blower pipes for blower usage Remove pipe retaining screw from blower housing.Align grooves in straight pipe with pegs of blower housing and slide pipe onto housing.
If you do find fuel leaks or discharges, stop using the product immediately and contact your ECHO DEALER to have it repaired. If the fuel ignites, it could cause burns and fire.
Engine operation Engine operation Starting the engine WARNING When starting the engine, observe the precautions described from Page 4 in the section "For safe use of your prod- uct" to ensure that you operate the product correctly. Failure to observe the precautions could cause an accident or injury, or even lead to a fatality. NOTE ...
If engine does not stop when stop switch is moved to 1. Stop switch 2. Throttle position lever STOP position, close choke - position - to stall engine. 3. Throttle trigger Have your ECHO dealer repair stop switch before using blower again.
Also, vacuuming up sticky material like mud or fallen leaves turning to leaf mold may cause fan case or pipe to clog.Con- tact the local ECHO dealer in your area should you notice a significant decrease in suction power or abnormal vibrations using your unit.
Operation Operating blower WARNING Always wear safety glasses, hearing protection, face filter mask and take all safety precautions or serious personal in- jury may result.Do not point the blower pipe in the direction of people or pets. IMPORTANT To avoid engine damage due to over revving, do not block blower pipe opening. NOTE Never use a higher speed setting than necessary to perform a task.
Time intervals are maximum. Actual use and your experience will determine the frequency of required maintenance. Maintenance and care If you have any questions or problems, please contact your ECHO DEALER. Cleaning air filter Tools required:25-50 mm (1-2 in.) Cleaning brush...
Page 22
1,000 feet above mean sea level (MSL). To maintain proper engine opera- tion above 1,000 feet MSL the carburetor must be adjusted by an authorized ECHO service dealer. Tools required:Screwdriver, tachometer (Echo P/N 99051130017) Parts required:None...
Page 23
If engine stops or stalls after full warm up, return the unit to your au- thorized ECHO dealer for repair. Check HI speed RPM at W.O.T. (Wide Open Throttle). HI speed RPM should be set to specifications found “Specifica- tions”...
Page 24
Maintenance and care Cooling system maintenance IMPORTANT To maintain proper engine operating temperature, cooling air must pass freely through the cylinder fin area. This flow of air car- ries combustion heat away from the engine. Overheating and engine seizure can occur when: ...
Page 25
The cylinder exhaust port must be inspected and cleaned of ex- cess carbon every 3 months or 90 hours of operation in order to maintain this engine within the emissions durability period. ECHO strongly recommends that you return your unit to your ECHO dealer for this important maintenance service.
ECHO DEALER. Do not attempt to dismantle the product. Consult your ECHO DEALER in the event of a problem that is not covered in the table above, or other such concerns. For spare parts and consumables, please use only genuine parts and designated products and components. Using parts from...
Fit the spark plug. (Do not connect the spark plug cap. ) Remove blower pipe assembly from unit. 1. Spark plug 2. Spark plug cap Please contact your ECHO DEALER in order to dispose of the product or its parts in compliance with national laws.
Do not use fuel containing methyl alcohol or more than 10 % of ethyl alcohol. Two stroke, air-cooled engine oil. ISO-L-EGD Stand- ard (ISO/CD 13738), JASO FC,FD grade and ECHO Premium 50 : 1 oil. Ratio 50 : 1 (2%)
KIORITZ CORPORATION 7-2 SUEHIROCHO 1-CHOME OHME; TOKYO 198-8711 JAPAN declares that the hereunder specified new unit: POWER BLOWER Brand: ECHO Type: PB-2350 assembled by: ECHO, INCORPORATED 400 Oakwood Road Lake Zurich, Illinois 60047-1564 U.S.A. complies with: * the requirements of Directive 98/37/EC (1998)