Above sketch show the connectors of the circulation pump on the main PCB.
From the component:
Measurement of the secondary windings of
Measurement of the primary windings of
the washing pump (white cable – blue
the washing pump. (118.2-135.9 Ω)
cable) (117.9-135.6 Ω)
Probes of the tester should be applied on to the related connectors as shown on the pictures.
Drain Pump
From the Main PCB:
C
T
141 Ω % ±10
DRAIN PUMP / LEILI
CN2.2 - CN2.4
KN2.4 - KN2.
MAIN PCB
Above sketch shows the connector terminals of the drain pump on the main PCB.