F5 (Inadequate Water Supply)
Water Tap
Make sure the water input tap is totally open and that there is no water cut off.
Water Inlet Hose
Close the water input tap, separate the water input hose from the tap and clean the filter at the connection
end of the hose.
Water Inlet Valve
The water inlet valve filter could be clogged.
The water inlet valve could be out of order. There could be a problem with the cable connection of water
inlet valve.
Floater
The floater switch could be out of order or have a problem with the cable connection.
Pressure Switch
The pressure switch of the heater could have a mechanical or cable connection problem.
Circulation Pump
The circulation pump could be out of order or have a problem with the cable connection.
An external part could be blocked to the circulation pump.
F6 (NTC Faulty)
NTC
The NTC could be out of order.
The NTC cable connection could be faulty. The NTC could have a short or an open circuit.
Main PCB
Check the power and resistance value of heater.
Check the cable connection of the heater.
F7 (Extreme Heating Up Faulty)
NTC
If the water temperature inside machine is higher than 77°C, the NTC could be out of order.
Main PCB
The main PCB could be out of order.
F8 (Inadequate Heat)
Heater
Check the power and resistance values.
Check the cable connection of the heater.
Main PCB
Check the Main PCB.