Figure 10: SO-1350 video camera attachments shown with SO-111-RF microscope Figure 11: Adjusting focus friction on the SO-111-RF Microscope Figure 12: Replacing the mould pellet – standard SO-111-R microscope shown Figure 13: Replacing the mould pellet – microscope fitted with video camera Issue number 1.0...
Apart from those instructions within this manual, there are no user-serviceable parts in this microscope. Scan Optics will retain the discretion to advise whether any repairs may be taken out by external qualified technical personnel, or whether part(s) of the microscope must be returned to the manufacturer’s premises for service or repairs to be carried out under warranty or otherwise.
Page 4
GUIDE HANDLE (OPTIONAL) TOOL KIT FOCUS ZOOM KNOB KNOB HORIZONTAL ARM SAFETY CLAMP PILLAR MOUNT POWER SUPPLY FLOOR STAND PILLAR FLOOR STAND BASE Figure 2: SO-111-R Microscope, shown with SO-331 Floor stand Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...
Pupillary distance setter SO-1510 Side handle Guide handle *Note that in SO-111-R/RF microscopes supplied with the SO-331 floor stand, the power supply assembly is mounted on a pillar fitting, not a G-clamp. Refer to this manual for details. Issue number 1.0...
CAUTION: • Scan Optics recommend that ALL packaging materials be retained by the user in a safe place, in case of future transit needs. • All covers are intended to be sterilised before any operating procedures.
Place the pillar fitting/power supply assembly on the pillar and tighten the two grub screws to fix the assembly in place. Continue assembling the microscope from step 2 of the instructions for table mounting. Figure 3: Assembling the SO-111-RF Microscope Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...
Page 8
SO-111-R/RF Ophthalmic Microscope User Manual Page 8 of 22 Figure 4: Assembling the SO-111-R Microscope with SO-331 Floor stand Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...
The guide handle may be used to manoeuvre the microscope once the appropriate friction has been set on the other knobs. Figure 6: Articulated arm features Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...
Use the manual light intensity adjustment and focus speed adjustment (SO-111-RF only) to obtain suitable settings. Note that lamp life will be extended if a lower light intensity setting is used. Figure 7: SO-111-R/RF Power supply top panel Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...
Page 12 of 22 LAMPHOUSE AND LAMP The lamp house on the SO-111-R ophthalmic microscope produces a coaxial light that provides a red fundus reflex from the back of the eye. The intensity of the light may be controlled from the top panel of the power supply. The lamp supplied has a rated average life of 50 hours, but the actual life of the lamp will depend on the intensity setting normally used.
The central pedal is disabled in this model. The focus knob may still be used to focus the microscope manually. However, Scan Optics recommends that the foot control be disconnected if this method is used in preference. This will prevent any accidental motor-driven movement that may counteract the manual focusing action.
(or the suer’s preferred zoom setting). Then observe the image on the monitor. If necessary, adjust the video camera focus setting located on the SZ-CTV unit to achieve a crisp image. Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...
Page 15
SO-111-R/RF Ophthalmic Microscope User Manual Page 15 of 22 Figure 10: SO-1350 video camera attachments shown with SO-111-RF microscope Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...
With the exception of the anti-mould pellet, no parts inside the optical head of the instrument can be serviced by the user. Attempts to dismantle the optical head or prism cover will make any warranty void. Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...
Hold the large gear in one hand while unscrewing the knob out to decrease the friction. Lock the grubscrews and check for the desired friction setting. Replace the focus drive cover. Figure 11: Adjusting focus friction on the SO-111-RF Microscope Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...
Page 18 of 22 MOULD PELLET REPLACEMENT Scan Optics microscopes are fitted with mould protection which lasts for approximately 3 years, however, this is dependent on the storage conditions and humidity of the local environment. In extreme tropical climates, it may be necessary to change the mould protection as frequently as every year.
Page 19
Replace the pellet as above Replace the beam splitter carefully and secure the head back in the bonder arm. Figure 13: Replacing the mould pellet – microscope fitted with video camera Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...
Focus right eye first through RHS eyepiece then adjust LHS eyepiece to compensate for error Microscope unsteady Unstable surface Stiffen mounting surface with a plate Knobs loose Tighten adjustment knobs as necessary Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...
MAINS POWER 220-240V/0.2A; 110-120V/0.4A OUTPUT 12V 50W INTENSITY CONTROL Continuous EARTHING via earth lead on mains cable (green/yellow) FUSE 250V/3A 20x5 mm CABLES Mains: Length 5 metres Battery: Length 5 metres Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...
Page 22
Pantograph arm vertical range 320 mm (13") MATERIALS No ferrous metals to rust or corrode FOOT CONTROLS (SO-111-RF ONLY) FUNCTIONS Focus control (speed adjustable from power supply) SWITCHES IP67 rated (full immersion) sealed switches Issue number 1.0 X:\Current User Manuals\SO-111-R-RF User Manual v1.0.doc...