Power Supply Input Wiring Diagram - Toshiba RAS-05J2AVG-TR Installation Manual

Hide thumbs Also See for RAS-05J2AVG-TR:
Table of Contents

Advertisement

Available languages

Available languages

Power supply input at Indoor unit Terminal Block (Recommend)
Power supply
input
Power supply input at Outdoor unit Terminal Block (Optional)
INDOOR UNIT
OUTDOOR UNIT
CAUTION
1. The power supply must be same as the rated of air conditioner.
2. Prepare the power source for exclusive use with air conditioner.
3. Circuit breaker must be used for the power supply line of this air conditioner.
4. Be sure to comply power supply and connecting cable for size and wiring method.
5. Every wire must be connected firmly.
6. Perform wiring works so as to allow a general wiring capacity.
7. Wrong wiring connection may cause some electrical part burn out.
8. Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.
9. This product can be connected to main power supply.
Connection to fixed wiring : A switch which disconnects all poles and has a contact separation at least 3 mm must be incorporated in the fixed wiring.
1122950109_S04_182x257_52p_S_p70_181217_EN+TR+RU.indd 15

Power supply input Wiring Diagram

L
L
N
GND
CHASSIS
CHASSIS
EARTH
L
CHASSIS
CHASSIS
EARTH
Indoor
N
1 2 3
Terminal
Block
Outdoor
1 2 3
Terminal
Block
Indoor
N
1 2 3
Terminal
Block
Outdoor
1 2 3 L N
Terminal
Block
13
INDOOR UNIT
OUTDOOR UNIT
N
Power supply
L
input
GND
12/25/2018 10:46:59 AM