Haier 1U50JECFRA-3 Service Manual page 18

Outdoor unit dc inverter
Hide thumbs Also See for 1U50JECFRA-3:
Table of Contents

Advertisement

3
4
5
6
7
8
Remarks: The above are the maximum frequency limitations of the complete appliance which are
affected by the environment, and they have nothing to do with the ability of the indoor unit.
Refrigeration/dehumidification mode:
Serial No.
1
2
3
4
5
6
7
Remarks: the above are not only the maximum frequency limitations of the complete appliance
which are affected by the environment, but also the maximum ability limitation of the system. When the
starting ability is not the maximum, its maximum frequency limitation is calculated by the following
equations:
The frequency limitation which is affected by the temperature and under the condition of actual
ability the actual running system ability*the maximum frequency which is limited by the temperature
and under the condition of maximum ability/the maximum designing ability of the system
Refrigeration/dehumidification mode:
The indoor setting
airflow speed
The percentage of the
rated frequency K
(18K/24K)
Heating mode:
The indoor setting
airflow speed
The percentage of the
rated frequency K
(18K/24K)
The calculation of the actual output frequency:
F= F-ED-*(rated frequency) K
F-ED-*(rated frequency)= The frequency which is limited by the outdoor environment temperature
Notes:
Wh_c<-2
Wh_c<5
Wh_c<10
Wh_c<17
Wh_c<20
Wh_c> 20
Temperature scope
Wh_c<16
Wh_c<22
Wh_c<29
Wh_c<32
Wh_c<40
Wh_c<48
Wh_c>=48
Low
70%/700%
Low
80%/80%
16
Max_hz3
103HZ/87 HZ
Max_hz4
90HZ/76 HZ
Max_hz5
78HZ/67 HZ
Max_hz6
67HZ/62 HZ
Max_hz7
56HZ/44 HZ
Max_hz8
52HZ/39 HZ
Frequency limitation 18K/24K
Max_hz1
33HZ/30HZ
Max_hz2
43HZ/35 HZ
Max_hz3
55HZ/51 HZ
Max_hz4
63HZ/62 HZ
Max_hz5
75HZ/75 HZ
Max_hz6
63HZ/66 HZ
Max_hz7
53HZ/49 HZ
Medium
Quiet
85%/85%
42%/60%
Medium
Quiet
90%/90%
51%/60%
Domestic air conditioner
Functions and control