Download Print this page

DC SD40 Operating And Maintenance Instructions

Cold rinse

Advertisement

Quick Links

POWER
LAMP
(OPTIONAL DRAIN PUMP)
REMOVE DRAIN PLUG THEN
SWITCH THE MACHINE OFF
TO START THE AUTOMATIC
DRAIN PUMP CYCLE
POWER
SWITCH
PREPARATION
 CHECK THE DRAIN PLUG IS PUSHED FIRMLY IN PLACE AND FILTERS ARE PROPERLY SECURED.
 CHECK THE DETERGENT CHEMICAL ( RED ) AND RINSE AID CHEMICAL ( CLEAR ) SUPPLY TUBES - WITH FOOT VALVES - ARE SUBMERGED IN SUFFICIENT PRODUCT.
 CHECK THE DOOR IS CLOSED AND PRESS THE POWER SWITCH - THE GREEN POWER LAMP WILL COME ON.
 ALLOW 30 MINUTES FOR THE MACHINE TO FILL WITH WATER AND REACH THE CORRECT WASHING TEMPERATURE.THE MACHINE READY LAMP WILL COME ON.
OPERATION
 REMOVE ALL DEBRIS FROM THE GLASSES TO BE WASHED BEFORE PLACING THEM INTO THE BASKET.
 CLOSE THE DOOR - PRESS THE CYCLE START SWITCH - THE CYCLE LAMP WILL COME ON.
 AT THE END OF THE CYCLE THE WASH CYCLE LAMP WILL GO OUT .SHORT BURSTS OF THE COLD RINSE SWITCH WILL COOL THE GLASSES FOR SERVICE.
 OPEN THE DOOR AND PULL OUT THE BASKET.ALLOW EXCESS WATER TO RUN OFF BEFORE REMOVING.
ROUTINE MAINTENANCE
 AT THE END OF A SESSION TURN OFF THE POWER SWITCH. DO NOT REMOVE THE FILTER AT THIS STAGE.
 REMOVE THE DRAIN PLUG - THE WASH TANK WILL EMPTY - (MACHINES FITTED WITH DRAIN PUMP WILL AUTOMATICALLY START TO PUMP THE WATER OUT).
 COLLECT THE DEBRIS AND REMOVE FROM THE WASH TANK.
 CLEAN AROUND THE WASH TANK - DOOR SURROUNDS AND HINGES WITH AN 'ADDIS'' TYPE WASHING UP BRUSH AND CLEANING CLOTH.
 DO NOT USE CHLORIDE OR BLEACH CONTAINING BASED CLEANING SOLUTIONS OR ABRASIVES WHEN CLEANING THE WASH TANK.
 TAKE OUT THE MAIN FILTER - CLEAN THOROUGHLY AND REPLACE .
 DO NOT ALLOW DEBRIS TO GO DOWN THROUGH THE FIXED FILTER AND OUTLET HOLE AS THIS MAY DAMAGE YOUR MACHINE.
 REGULARLY CHECK RINSE JETS AND WASH JETS ARE CLEAR OF DEBRIS OR LIME SCALE - REMOVE IF NECESSARY BY UNSCREWING THE RINSE ARM NUT THAT HOLDS THE
RINSE ARM IN PLACE - REMOVE THE RINSE PIN THAT HOLDS THE WASH ARM IN PLACE - CLEAN BOTH THOROUGHLY AND REASSEMBLE.
WATER SOFTENER
 REMEMBER TO REGENERATE THE EXTERNAL WATER SOFTENER IF FITTED REGULARLY. ENSURE THAT THE WATER VALVES ARE TURNED BACK ON TO SUPPLY
THE MACHINE WITH MAINS PRESSURE SOFTENED WATER.
RINSE ARM
RINSE
JETS
WASH ARM
SERVICE CALLS TO RECTIFY FAULTS CAUSED BY `THE LACK OF ROUTINE MAINTENANCE` WILL BE CHARGED FOR
OPERATING AND MAINTENANCE INSTRUCTIONS
SD40 (COLD RINSE)
WASH CYCLE
LAMP
CYCLE START
SWITCH
RINSE ARM NUT
RINSE PIN
WASH JETS
AND YOUR WARRANTY MAY BE AFFECTED
www.directcatering.co.uk
COLD RINSE
SWITCH
FOOT VALVES FOR
CHEMICAL
CONTAINER TUBES
MACHINE READY
LAMP
DRAIN PLUG
MAIN FILTER
FIXED FILTER
OUTLET HOLE

Advertisement

loading

Summary of Contents for DC SD40

  • Page 1 OPERATING AND MAINTENANCE INSTRUCTIONS SD40 (COLD RINSE) POWER WASH CYCLE MACHINE READY LAMP LAMP LAMP (OPTIONAL DRAIN PUMP) REMOVE DRAIN PLUG THEN SWITCH THE MACHINE OFF TO START THE AUTOMATIC DRAIN PUMP CYCLE COLD RINSE POWER CYCLE START SWITCH SWITCH...
  • Page 2 DC SERIES WARE WASHING INSTALLATION AND COMMISSIONING GUIDE General safety • The following installation procedures have been produced in conjunction with the user instructions and safety regulations book supplied with this machine. • Installation and servicing must be carried out by qualified catering engineers trained for this type of machine.