Terex Genie Lift Guard GS-30 Operator's Manual Supplement

Terex Genie Lift Guard GS-30 Operator's Manual Supplement

Contact alarm

Advertisement

Quick Links

Operator's Manual Supplement
Lift Guard™ Contact Alarm
GS
-30
GS
-32
GS
-46
GS
-47
First Edition
Second Printing
Part No. 1288739GT

Advertisement

Table of Contents
loading

Summary of Contents for Terex Genie Lift Guard GS-30

  • Page 1 Operator's Manual Supplement Lift Guard™ Contact Alarm ™ ™ ™ ™ First Edition Second Printing Part No. 1288739GT...
  • Page 2 Operator's Manual Supplement First Edition • Second Printing Introduction Introduction Lift Guard Contact Alarm System The Lift Guard Contact Alarm system is designed to alert the operator, occupants and ground personnel to a potential hazard when an obstruction makes contact with the secondary guarding system.
  • Page 3: Pre-Operation Inspection

    First Edition • Second Printing Operator's Manual Supplement Introduction Contact Alarm Safety Pre-operation Inspection Read, understand and obey all warnings and  Be sure that the operator’s, safety manual, instructions provided with the contact alarm. responsibilities manual and any necessary Do not exceed the rated platform capacity.
  • Page 4: Function Test

    Operator's Manual Supplement First Edition • Second Printing Introduction Function Test Note: Perform this procedure from the platform controls in an area free of obstructions. Activate platform up. Move and hold the contact alarm in any direction. Platform up function stops, the beacons flash and the alarm sounds.
  • Page 5 First Edition • Second Printing Operator's Manual Supplement Operating Instructions Operating Instructions Operating Instructions Contact alarm activated, beacon lights flash and an audible alarm sounds. Lift and drive functions will not operate from the platform controls. Note: The potential hazard must be acknowledged by the operator to continue operating the machine.
  • Page 6: Installation Instructions

    Operator's Manual Supplement First Edition • Second Printing Installation Instructions Installation Instructions Attention: The Lift Guard™ Contact Alarm can only be installed on machines with the "Proportional Lift" control system. It is not compatible with "2 Speed Lift" control systems. Observe and Obey: Refer to the illustrations to determine which control ...
  • Page 7: Tools Required

    First Edition • Second Printing Operator's Manual Supplement Installation Instructions Tools Required: Contents of Kit 1288736GT 3/8 inch wrench GS-1530 / GS-1532 (14.5 inch / 37 cm) 7/16 inch wrench Description Genie part Qty. number 3/8 inch socket Cable tie, 7.375 inch / 19 cm 6578GT 7/16 inch socket Button cable tie, 14.75 inch / 37,5 cm...
  • Page 8 Operator's Manual Supplement First Edition • Second Printing Installation Instructions Contents of Kit 1288737GT Contents of Kit 1288738GT GS-1930 / GS-1932 (14.5 inch / 37 cm) GS-2032 (14.5 inch / 37 cm) Description Genie part Qty. Description Genie part Qty. number number Cable tie, 7.375 inch / 19 cm...
  • Page 9 First Edition • Second Printing Operator's Manual Supplement Installation Instructions Contents of Kit 1289293GT Contents of Kit 1289294GT GS-2632 (14.5 inch / 37 cm) GS-3232 (14.5 inch / 37 cm) Description Genie part Qty. Description Genie part Qty. number number Cable tie, 7.375 inch / 19 cm 6578GT Cable tie, 7.375 inch / 19 cm...
  • Page 10 Operator's Manual Supplement First Edition • Second Printing Installation Instructions Contents of Kit 1289420GT Contents of Kit 1289421GT GS-2046 (14.5 inch / 37 cm) GS-2646 (14.5 inch / 37 cm) Description Genie part Qty. Description Qty. number Cable tie, 7.375 inch / 19 cm 6578GT Cable tie, 7.375 inch / 19 cm 6578GT...
  • Page 11 First Edition • Second Printing Operator's Manual Supplement Installation Instructions Contents of Kit 1289422GT Contents of Kit 1289295GT GS-3246 (14.5 inch / 37 cm) GS-4047 (14.5 inch / 37 cm) Description Genie part Qty. Description Genie part Qty. number number Cable tie, 7.375 inch / 19 cm 6578GT Cable tie, 7.375 inch / 19 cm...
  • Page 12 Operator's Manual Supplement First Edition • Second Printing Installation Instructions Note: Perform this procedure on a firm, level 11 Remove the white wire from the harness surface. assembly and discard. Turn the key switch to ground control and pull 12 Remove the white plug from connector J1 pin out the red Emergency Stop button to the on 11 and discard.
  • Page 13 First Edition • Second Printing Operator's Manual Supplement Installation Instructions 19 Connect the cable to the ESTOP splice 25 Secure the cable guide to the platform using harness. the provided retaining fasteners. Do not tighten at this time. 20 Route the cable through the link stack to the platform with the existing cables.
  • Page 14 Operator's Manual Supplement First Edition • Second Printing Installation Instructions 34 Secure the cable guide to the platform with the 42 Connect the lift guard assembly to the harness retaining fasteners set aside. in the cable guide at the non-steer end of the machine with the 45 inch link cable.
  • Page 15 First Edition • Second Printing Operator's Manual Supplement Installation Instructions GS-30 and GS-32 models GS-46 and GS-47 models ™ Part No. 1288739GT Lift Guard Contact Alarm...
  • Page 16 Operator's Manual Supplement First Edition • Second Printing Installation Instructions ™ Lift Guard Contact Alarm Part No. 1288739GT...
  • Page 17: Software Update

    First Edition • Second Printing Operator's Manual Supplement Software Update Software Update Machines with a control system software revision Press the ground control scroll down button. of "P" or higher do not require a software upgrade. Result: The GCON LCD will show the software Machines with revision of "N"...
  • Page 18 Operator's Manual Supplement First Edition • Second Printing Software Update Firmware Site Download Activating or Deactivating the Contact Alarm Note: Access to the internet is required to perform this procedure. Note: The contact alarm must be activated in the options menu for the machine to function properly Click on the Hyperlink below or open an when it has been installed on the machine.
  • Page 19 First Edition • Second Printing Operator's Manual Supplement Software Update Pull out the red Emergency Stop button to the on position at the ground controls. Result: The ground controls LCD display will show the following: Use the ground control menu buttons to select machine Options.

Table of Contents