  • Page 1 SPLIT TYPE ROOM AIR CONDITION OPERATION MANUAL AS09FBAHRA AS20S2SF2FA-1 AS25S2SF2FA-1 AS12FBAHRA AS35S2SF2FA-1 AS18FDAHRA AS42S2SF2FA-1 AS24FEAHRA AS50S2SF2FA-1 AS20S2SF2FA AS71S2SF2FA-1 AS25S2SF2FA AS35S2SF2FA AS50S2SF2FA AS71S2SF2FA Please read this operation manual before using the air conditioner. Keep this operation manual for future reference This appliance is filled with R32.
  • Page 2 Read the precautions in this manual This appliance is filled with R32. carefully before operating the unit. Keep this manual where the user can easily nd it. WARNING: · Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • Page 3: Table Of Contents

    Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLATION MAINTENANCE CAUTIONS TROUBLE SHOOTING...
  • Page 4: Parts And Functions

    Parts and Functions Remote controller Indoor Unit Additional functions display Supplemented Display board electrical Operation mode QUIET SLEEP HEALTH TURBO Inlet heating (inside) Remote controller 9. QUIET button 10. HEAT button Inlet grille 11. COOL button 12. SWING LEFT/RIGHT button 13.
  • Page 5: Operation

    Operation Base Operation Emergency operation and test operation Emergency Operation: Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner Remote controller can run automatically for a while. When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation.
  • Page 6 Operation Sleep Operation 4. In FAN mode It has no SLEEP function. Press button to enter additional options, when 5.Set the wind speed change when sleeping cycle display to will flash. And then press If the wind speed is high or middle before setting for the enter to sleep function.
  • Page 7 EUROPEAN REGULATIONS Operation CONFORMITY FOR THE MODELS Climate:T1 Voltage:230V Timer On/Off On-Off Operation 1.After unit starts, select your desired operation mode. All the products are in conformity with the following 2.Press TIMER button to change TIMER mode. Every European provision: time the button is pressed, display changes as follows: - Low Voltage Directive 2014/35/EU Remote controller:...
  • Page 8: Indoor Unit Installation

    Indoor Unit Installation Necessary Tools for Installation Power Source Torque wrench Driver Before inserting power into receptacle, check the voltage without (17mm,22mm,26mm) Nipper fail. Pipe cutter Hacksaw The power supply is the same as the corresponding nameplate. Flaring tool Hole core drill Install an exclusive branch circuit of the power.
  • Page 9 Indoor Unit Installation [ Left Left-rear piping ] Fitting of the Mounting Plate and Positioning of the wall Hole In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping When the mounting plate is first fixed direction to the mark of hole for left-rear piping which is marked on heat insulation materials.
  • Page 10 When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall Lean Damage of flare Crack Partial Too outside hole, in which the pipe has already existed. 2. Pull out the cable on the front side, and connect the cable On Drainage making a loop.
  • Page 11: Maintenance

    Maintenance For Smart Use of The Air Conditioner Remote Controller Indoor Body Setting of proper room Do not block the air inlet temperature or outlet Proper wipe the air conditioner by using a temperature soft and dry cloth.For serious stains, use a neutral detergent diluted with Do not usewater,wipe the controller water.Wring the water out of the...
  • Page 12: Cautions

    Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. WARNING Check proper When abnormality such as burnt-small found, Use an exclusive immediately stop the operation button and installation of the power source...
  • Page 13: Trouble Shooting

    30 seconds later, cutting off the power. Are there too much heat sources or too many people in the room during cooling operation? Haier Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010 Haier Website: www.haier.com Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010...