Download Print this page

T&D RTR-600 Series User Manual

Wireless food core temperature data logger
Hide thumbs Also See for RTR-600 Series:

Advertisement

Quick Links

Wireless Food Core Temperature Data Logger
RTR-600 Series
RTR-602 Users Manual
Thank you for purchasing our product.
Carefully read this instruction manual before using this unit.
RTR-602S
RTR-602L
RTR-602ES
RTR-602EL
Common Accessories: Manual Set (Warranty Included)
In this manual, RTR-602S, RTR-602L, RTR-602ES, and RTR-602EL are referred to as "RTR-602",
"Remote Unit(s)", or simply as "device(s)".
tandd.com
© Copyright T&D Corporation. All rights reserved. 2022. 01 16504390060 6th Edition
Before Using this Product
• The RTR-602 Units function as Remote Units. They require Base Units to carry out wireless communication. Before getting ready and setting up
the Remote Unit, make sure to first get ready and setup the Base Unit(s).
• To use RTR-602, it is necessary to make operation settings via the software "RTR-600 Settings Utility".
For details about the operation settings via the software, refer to the "RTR500BW+RTR-600 Setup Guide (PDF)". Both the software and manual
can be downloaded from the T&D Website.
• To carry out setup of RTR-602, a Battery Charge Dock with USB communication function "RTR-600BD" (sold separately) is also necessary.
RTR-602 Specifications
Measurement Channels
Temperature 1ch
Sensor
Platinum Resistance (Pt1000)
Measurement Units
°C , °F
Measurement Range
-60 to 250°C
±0.5°C at -10 to 150°C
Accuracy
±1.0°C at -60 to -10°C, 150 to 250°C
Measurement Resolution 0.1°C
Response Time (90%):
Responsiveness
Approx. 60 sec. (in air) / Approx. 3 sec. (in agitated water)
Measurement
0.5 seconds
/ Display Interval
Recording Items
Temperature, Measurement Time, User, Item, Judgment Result
Logging Capacity
1,800 readings
Recording Mode
Endless (Overwrite oldest data when capacity is full)
Short Range Wireless Communication
Frequency Range: 902 to 928MHz
Communication
RF Power: 7mW
Interfaces
Transmission Range: About 50 meters (if unobstructed and direct)
Optical Communication
Data Download Time (for 1,800 readings): Approx. 2 minutes
Communication Time
An additional 30 seconds should be added for each Repeater. (*1)
Two included AAA Ni-MH batteries (Non-Contact Charging System) (*2)
Power
Battery Life
Approx. 24 hours (for Continuous Operation with Backlight Always ON)
H 181.3 mm × W 53.5 mm × D 53.5 mm (excluding sensor)
Dimensions
Sensor Length: Short type 135 mm, Long type 310 mm
Cable Length: 900 mm
RTR-602S (Short Sensor) Approx. 200 g
RTR-602L (Long Sensor) Approx. 210 g
Weight
RTR-602ES (Cable Type Short Sensor) Approx. 250 g
RTR-602EL (Cable Type Long Sensor) Approx. 260 g
Operating Environment
-10 to 60°C
Waterproof Capacity
IP68: Submersible
PC Software (Windows)
Software (*3)
Base Unit/Repeater Settings: RTR500BW for Windows
Remote Unit Settings: RTR-600 Settings Utility
Compatible Base Units /
Base Units: RTR500BW / 500BC (*4), RTR-500NW / 500AW / 500 (*4)
Repeaters
Repeaters: RTR500BC, RTR-500
*1: When using RTR500BW as Base Unit and RTR500BC as Repeater. Depending upon conditions
it may take up to an additional 2 minutes.
*2: A Battery Charge Dock (RTR-600BD) needs to be purchased separately.
*3: Software on CD-ROM is not supplied with the product. Free software download and
information on OS compatibility is available on the Software page of our website at tandd.
com/software/.
*4: Customers wishing to use the RTR500BC or RTR-500 as a Base Unit, please contact your
local distributor for the communications protocol specifications to write your own software.
The specifications listed above are subject to change without notice.
Part Names and Functions
LED (Orange)
By pressing the <REC> button, the lamp will turn on when a temperature
measurement is recorded.
Judgment LED
The Judgment result of temperature measurement will be shown. Out of
(Red / Green)
Range: Red LED will blink. Within Range: Green LED will blink.
<REC> Button
When this button is pressed, the Temperature, Date / Time, User Name,
Item, and Judgment Result at the time of pressing are recorded into the
RTR-602.
Operation Buttons
<ENT>
Press to enter the settings menu or confirm a setting.
By pressing this button, the menu will be displayed. Also, press to return
<MENU>
to the previous screen.
Press to move the arrow cursor up and down or scroll the screen.
Power Button
Press to turn the power ON or OFF. The automatic power-off function auto-
matically turns off the power after about five minutes of inactivity.
Optical Commu-
Do not shield the communication area with a tape as it may cause
nication Area
communication errors.
Sensor Tip Shape
Each sensor type has a different tip shape: the long type sensor has a round
tip; and the short type sensor has a sharp tip (for piercing target object).
Sensor Materials: Stainless Steel (SUS316)
Handgrip Materials: Flame-retardant PPE/PA6 (Temperature Durability: About 170°C)
Cable Materials: Fluoropolymer Coated Electrical Wire Cable Length: 900 mm
Safety Precautions and Instructions
To ensure safety obey all of the following warnings.
The following items should be strictly obeyed for the safe usage of this product, and for protecting yourself and other people from bodily harm and/
or damage to property. Before using this product, please read the following carefully and fully understand the contents.
DANGER
Failure to follow the instructions with this symbol could cause serious injury or even death.
DO NOT USE THIS PRODUCT IN WAYS OTHER THAN ITS IN-
TENDED PURPOSE
This product has been designed to measure the
temperature of food and liquids. Do not use it for any
purpose other than for which it was designed.
Because the sensor has a sharp tip, there is a risk of
accidentally stabbing people and/or objects. Do not
use the sensor for any purpose other than measuring
the temperature of objects for which it was designed.
CLEAN and STERILIZE UNITS BEFORE
If a unit gets dirty or oily, wipe it with a
AND AFTER USE
clean cloth dipped in alcohol.
Before and after
NEVER use an acid, alkaline, or chlorine based
using, please clean
detergent. This will cause harm to the electric
to remove any
components in the unit or the battery charger.
substances attached
to the surface and
sterilize the units in
order to prevent the
growth of bacteria.
Failure to follow the instructions with this symbol could
CAUTION
cause personal injury or physical damage to equipment.
- Do not disassemble, repair or modify the unit and/or accessories.
- Do not forcibly insert the sensor into hard objects such as frozen food.
It may cause to sensor breakage, leading to unexpected accidents
and injury.
- Do not cut or process the sensor cables. Also, do not twist, pull or
swing any of the cables.
- We are not responsible for any damage, malfunction or trouble,
whether direct or indirect, caused by the use of our product.
- To prevent damage to the unit from static electricity, remove static
electricity from your body before touching the unit.
Important Notices and Disclaimers
In order to properly use this product, please carefully read this document
before using.
- All rights of the attached documents belong to T&D Corporation. It
is prohibited to use, duplicate and/or arrange a part or whole of the
attached documents without the permission of T&D Corporation.
- All registered trademarks, company names, product names and logos
mentioned herein are the property of T&D Corporation or of their
respective owners.
- Specifications, design and other contents outlined in this document
are subject to change without notice.
- Please follow the safety precautions outlined in this document
carefully.
- We cannot guarantee nor are we responsible for safety if this product
is used in any manner other than was intended.
- On-screen messages in this document may vary slightly from the
actual messages.
- Please notify the shop where you purchased this product or T&D
Corporation of any mistakes, errors or unclear explanations in this
document.
- T&D Corporation accepts no responsibility for any damage or loss of
income caused by the use of our product.
- Please read the warranty and provisions for free repair carefully.
Information Regarding Product Disposal
- This product contains recyclable Ni-MH batteries.
- If you wish to dispose of the unit, please contact your local distributor.
PLACE AND STORE IN A SAFE PLACE
Avoid placing the unit in unstable areas
exposed to vibration, slippery surfaces,
or within reach of small children. When
not in use, put a cover on the sensor
tip and store in a safe place.
DO NOT TOUCH SENSOR IMME-
DIATELY AFTER MEASUREMENT
Please be careful when using in
extreme hot or cold environments;
touching the unit may cause burns
or frostbite.
Compliance Information
This device complies with part 15 of FCC Rules and Innovation,
Science and Economic Development Canada's licence-exempt RSS(s).
Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
Le présent appareil est conforme à la partie 15 des règles de la FCC
et aux normes des CNR d'Innovation, Sciences et Développement
économique Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit
accepter tout brouillage subi, même si le brouillage est susceptible
d'en compromettre le fonctionnement.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: Changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to
operate the equipment.
This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.

Advertisement

loading

Summary of Contents for T&D RTR-600 Series

  • Page 1 Wireless Food Core Temperature Data Logger Measurement Channels Temperature 1ch Safety Precautions and Instructions Sensor Platinum Resistance (Pt1000) RTR-600 Series Measurement Units °C , °F To ensure safety obey all of the following warnings. Measurement Range -60 to 250°C RTR-602 Users Manual ±0.5°C at -10 to 150°C...
  • Page 2 How to Read the LCD Display Menu Contents Operations Table Top Screen [Check Data] > [Data List] > [Check Data] By turning the power to ON, the Top Screen, such as below, will appear. = Press the <MENU> button. By selecting the [Check Data] menu, all recorded Screen data in the Remote Unit is displayed in a list in = Press the <ENT>...

This manual is also suitable for:

Rtr-602Rtr-602sRtr-602lRtr-602esRtr-602el