T&D TR-74Ui Introductory Manual

T&D TR-74Ui Introductory Manual

Illuminance uv recorder
Hide thumbs Also See for TR-74Ui:

Advertisement

Quick Links

Introductory Manual
Thank you for purchasing our product.
Carefully read this instruction manual
before using this Unit.
This "Introductory Manual" explains in a
simple manner how to set up the TR-74Ui and
some of its basic operations. For details about
the functions and features of the software
"Illuminance UV Recorder for Windows" and
how to use them, please refer to the "Operation
Guide (Help)" included in the software.
© Copyright T&D Corporation. All rights reserved.
TR-74U i
2010.08 16504570007 2nd Edition

Advertisement

Table of Contents
loading

Summary of Contents for T&D TR-74Ui

  • Page 1 Carefully read this instruction manual before using this Unit. This "Introductory Manual" explains in a simple manner how to set up the TR-74Ui and some of its basic operations. For details about the functions and features of the software "Illuminance UV Recorder for Windows" and how to use them, please refer to the "Operation...
  • Page 2 Notices about this Introductory Manual In order to properly use this product, please carefully read this manual before using. T&D Corporation accepts no responsibility for any malfunction of and/or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty.
  • Page 3 Software User Agreement Disclaimers 1. Although T&D Corporation has made operational tests on our software Illuminance UV Recorder for Windows, we cannot guarantee that all operations will work properly under all conditions. 2. T&D Corporation shall not accept any responsibility for any damage whether direct or indirect that results from the usage of Illuminance UV Recorder for Windows.
  • Page 4 FCC Compliance Statement for American Users This device complies with Part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 5: Table Of Contents

    Contents Safety Precautions and Instructions --------------------------------- 2 Basic Procedures ---------------------------------------------------------- 9 What is TR-74Ui Illuminance UV Recorder? --------------------- 10 TR-74Ui Appearance Diagram and Part Names --------------- 12 Reading the LCD Display --------------------------------------------- 14 Main Display Messages ----------------------------------------------- 15 Operations via Buttons on TR-74Ui -------------------------------- 17...
  • Page 6: Safety Precautions And Instructions

    The following items should be strictly obeyed for the safe usage of this Unit, and for protecting yourself and other people from bodily harm and/or damage to property. The TR-74Ui Illuminance UV Recorder is hereafter referred to as "a Unit" or "the Unit" in this manual. Explanation of Symbols...
  • Page 7 DANGER When installing and using the Unit, make sure to follow all warnings and directions from your computer manufacturer. Do not take apart, repair or modify the Unit. Doing so may cause fire or electrocution. If water or a foreign body enters into the Unit, immediately turn OFF the power, remove batteries, and stop using.
  • Page 8 CAUTION This Unit is not waterproof. If the Unit gets dirty, wipe it with a clean cloth and a mild detergent. Harmful gases or chemicals may cause corrosion and/or other danger to the Unit. Also, by coming in contact with hazardous substances, harm may occur to the people handling the Unit.
  • Page 9 We shall not guarantee the operation of the Unit if you have connected it to your computer using a USB hub or a USB extension cable. Please do not insert your fingers or any foreign objects into any of the Units' jacks. Do not use any other batteries than those that are specified in this Introductory Manual.
  • Page 10 When using the Illuminance UV Sensor ISA-3151, please take note of the following: Do not connect the ISA-3151 sensor to any data logger other than the TR-74Ui. Use the sensor within the operating environment specifications. When measuring ultraviolet light or other light which may...
  • Page 11 When using the included the Temperature/Humidity Sensor THA-3151, please take note of the following: Do not connect Sensor THA-3151 to any data loggers other than TR-74Ui. Use the sensor within the operating environment specifications. If extremely severe temperature changes occur, the humidity measurements may appear abnormal.
  • Page 12 If you wish to extend the length of the sensor cable, please purchase our optional sensor extension cable. Do not cut or process the sensor cables. "Adjustment Settings" made in the supplied software are saved to the sensor. Therefore, when a sensor is replaced, it is necessary to re-make any desired adjustment settings before using the new sensor.
  • Page 13: Basic Procedures

    1. Make Settings for Device Names, Recording Intervals and Recording Modes 2. Start Recording 3. Downloading Data and Displaying Graphs 1. Connect the TR-74Ui with a USB cable to a computer 2. Download Data via Software 3. Display Graphs via Software NOTE: Details about "Making TR-74Ui Unit Settings"...
  • Page 14: What Is Tr-74Ui Illuminance Uv Recorder

    Cumulative Illuminance and Cumulative Amount of UV Light in the LCD display. The data recorded into the TR-74Ui Units can then be downloaded quickly to your computer whereby with our exclusive software you can process the data into graphs, tables, and/or print it out to help you analyze that data.
  • Page 15 Package Contents The following items are included in the package: Illuminance UV Illuminance UV Temperature/ Software CD-ROM Recorder TR-74Ui Sensor Humidity Sensor ISA-3151 (cable THA-3151 (cable length: 1.5 m) length: 1.5 m) AA Alkaline Battery USB Communication Introductory Manual Cable...
  • Page 16: Tr-74Ui Appearance Diagram And Part Names

    TR-74Ui Appearance Diagram and Part Names Main Unit unit : millimeters LCD Display DISPLAY Button: Pressing this button will change the LCD Display Pattern. INTERVAL Button: Pressing this button will make it possible to make or change Recording Interval settings.
  • Page 17 Illuminance UV Sensor (ISA-3151) 1500 26.5 � 2 .6 12.6 unit : millimeters Illuminance Sensor Area Ultraviolet Sensor Area Temperature/Humidity Sensor (THA-3151) 51.5 1500 26.5 � 2 .6 unit : millimeters Temperature/Humidity Sensor Area...
  • Page 18: Reading The Lcd Display

    Reading the LCD Display Recording The recording status will appear. Mark ON: Recording in progress. BLINKING: Waiting for programmed start. OFF: Recording has been stopped. Data Capacity After every 2,000 readings the scale will be marked from left to right. Storage capacity is 8,000 readings. Scale COM Mark Normally, this mark will not be displayed.
  • Page 19: Main Display Messages

    Main Display Messages The following are the main display messages that appear on the LCD display. FULL (Storage Capacity FULL) Upon reaching storage capacity of 8,000 readings, "FULL" will appear on the LCD display. When this message appears, recording has been stopped. (Only when recording in ONETIME mode will this be displayed.) Sensor Error This will be displayed when a sensor has not been connected, has...
  • Page 20 Nothing Appears If after going into sleep mode above, the battery is further left unchanged the display will automatically shut off. If that occurs, all recorded data will be lost. See "Installing Battery" on page 20 and change the battery.
  • Page 21: Operations Via Buttons On Tr-74Ui

    Operations via Buttons on TR-74Ui NOTE: If no operations can be performed using buttons on the TR-74Ui Unit, it means the buttons have been deactivated via the software. POWER Button: Turning ON / OFF the Power During recording, the power cannot be turned off by pressing the button on the Unit.
  • Page 22: Interval Button: Setting / Checking Recording Interval

    Interval Button: Setting / Checking Recording Interval During recording or while waiting for a programmed recording to start via the software, recording interval settings cannot be made or changed. The factory default setting for the recording interval is 10 seconds. Setting the Recording Interval Press the INTERVAL button until the recording interval time appears on the LCD display.
  • Page 23: Display Button: Changing The Lcd Display Pattern

    Display Button: Changing the LCD Display Pattern There are two LCD display patterns for current readings: An Alternating Display and A Fixed Display. Alternating Display: The LCD display shows all or selected multiple measurement items. Make settings for measurement items to be displayed via the software. If the setting has been made so as to display all measurement items, the items will be shown alternatingly in the following order: Illuminance (lx, Klx) >>...
  • Page 24: Changing The Battery

    About Battery Life A TR-74Ui Unit can be used continuously for about six months with one AA Alkaline Battery. Battery life varies depending upon the type of battery, the battery performance, the measuring environment, and the frequency of communication.
  • Page 25: Installing The Software

    Installing the Software Before Installing the Software Is Windows operating properly? If Windows is not operating properly, "Illuminance UV Recorder for Windows" may not be installed correctly or it may not operate properly. Check the computer operating environment Please check whether the computer is operating properly by following the directions on page 44.
  • Page 26 Installation Procedure Do NOT connect a TR-74Ui Unit to the computer. Make sure to install the software before connecting the TR-74Ui to the computer. This explanation uses displays from Windows XP SP2. If your OS is Windows Vista or Windows 7, the window layout may be slightly different.
  • Page 27 4. The "Illuminance UV Recorder for Windows Setup Wizard" window will appear. Click the [Next] button 5. The "Software License Agreement" window will appear. Check "I accept the terms of the license agreement" Click the [Next] button 6. A window will appear where you can specify the folder into which the software program will be installed.
  • Page 28 7. A window will appear showing folders for selection; specify where you wish to register the software program in the list of program folders. Enter the desired program folder name if you wish to change It is also possible to choose a folder from the existing list If OK, click the [Next] button 8.
  • Page 29 Security Window in Windows Vista and Windows 7 Click the [Install] button 9. After installation has been completed, please click the [Finish] button. After installation has been completed, "Illuminance UV Recorder for Windows" will be registered in the Windows Start Menu.
  • Page 30: Getting The Tr-74Ui Ready To Use

    Getting the TR-74Ui Ready to Use 1. Install the Battery. Remove the battery cover and insert one AA alkaline battery, making sure that the – and + are in the correct direction. 2. Connect the Sensor. The Sensor Jacks are common for both sensors. The Temperature/ Humidity Sensor or the Illuminance UV Sensor can be connected to either of the Sensor Jacks.
  • Page 31: Connecting The Unit To The Computer

    Connect to a USB port on the computer For Windows XP By connecting a TR-74Ui to a computer, the [Found New Hardware Wizard] window will automatically open. Please follow the procedure on the next page to install the USB device driver.
  • Page 32: Installing The Usb Device Driver

    Installing the USB Device Driver 1. If you are using Windows XP, please follow the directions below. Check "No, not this time" Click the [Next] button Check "Install the software automatically (Recommended)" Click the [Next] button 2. The Installation process will begin. 3.
  • Page 33: If "Illuminance Uv Recorder For Windows" Does Not Run

    When using Windows XP, if multiple TR-74Ui Units are simultaneously connected to the same computer, they may not work properly.So please connect only one TR-74Ui Unit to the computer at a time. If the software does not run on your computer even after...
  • Page 34 1-3. Click on "System". 1-4. In the System Properties Window, click on the [Hardware] tab. 1-5. Click the [Device Manager] button to open the Device Manager window. [Hardware] Tab [Device Manager] Button...
  • Page 35 2. Connect the Unit to the computer with a USB cable and look at the icons displayed in the Device Manager window to check whether or not the USB device driver has been properly installed. If failed (example) If successful (example) Icons for an "Unknown Device"...
  • Page 36: Re-Installing The Usb Device Driver

    Re-installing the USB Device Driver 1. In the Device Manager window, right click on the icon for the "Unknown Device". 2. From the pop-up menu click on "Properties". 3. When the following window appears, click on the [Reinstall Driver] button to display the Wizard window. Click...
  • Page 37 4. If you are using Windows XP, please follow the directions below and move on to step 6. Check "No, not this time" Click the [Next] button Check "Install from a list or specific location (Advanced)" Click the [Next] button Check "Include this location in the search"...
  • Page 38 6. Specify the location of the device driver. Click the plus (+) sign next to the folder into which "Illuminance UV Recorder for Windows" was installed and specify "Driver TR-74Ui" as the driver location. Click the [OK] button to return to the Wizard window.
  • Page 39 Then click the [Next] button. For Windows XP For Windows Vista and Windows 7 Location Example: C:\Program Files\Illuminance UV Recorder for Windows\Driver TR-74Ui 8. The installation process will begin. Please note that the following warning messages may appear during installation.
  • Page 40 9. After installation has been completed, please click the [Finish] or [Close] button. 10. Please check whether the USB device driver has been properly installed. (See pages 29-31 for details)
  • Page 41: About The "Operation Guide

    About the "Operation Guide" NOTE: Very important information for the proper use of TR-74Ui is contained in the Operation Guide; please carefully read it before carrying out the Initial Settings. Please refer to it whenever you may have questions or problems.
  • Page 42: Troubleshooting

    five years when used at a normal temperature. Is it possible to use other companies’ sensors with a TR-74Ui? No, the TR-74Ui Unit is not compatible with other companies' sensors. If you wish to replace a sensor, please purchase one of our optional sensors.
  • Page 43: Options

    Options unit : millimeters Sensor Extension Cable (TR-1C30) TR-1C30 TR-1C30: 3000 � 8 .4 Cable Length: 3 m Temperature Durability: -25 to 60°C � 8 � 8 Usage Figure ISA-3151 THA-3151 TR-1C30 It is possible to use up to three extension cables for each sensor. USB Communication Cable (US-15C) 1500 Connector:...
  • Page 44: Specifications

    Specifications TR-74Ui Unit Measurement Illuminance UV Intensity Temperature Humidity Items Number of 1 channel for each Measurement Item Channels Unit of lx, Klx mW/cm² °C / °F Measurement Display Range of Cumulative 0 to 90,000,000 lx·h 0 to 62 W/cm²·h −...
  • Page 45 Illuminance UV Sensor ISA-3151 Illuminance Measurement Items Ultraviolet Light Measurement Range 0 to 130,000 lx 0 to 30 mW/cm² Measurement Minimum: 0.01 lx Minimum: 0.001 mW/cm² Resolution 10 to 100,000 lx: ±5% 0.1 to 30 mW/cm²: ±5% Measuring Accuracy (At 25°C 50%RH) (At 25°C 50%RH) Relative Spectral Approximated to the CIE standard...
  • Page 46 Relative Spectral Response Characteristics Graph (Illuminance) Broken line: the CIE standard response function V ( λ ) Solid line: ISA-3151 Relative Spectral Response Characteristics Graph (UV) ISA-3151...
  • Page 47 Cosine Correction Characteristics (Illuminance) Broken line: cos θ Solid line: Measurement Value Cosine Correction Characteristics (UV) Broken line: cos θ Solid line: Measurement Values...
  • Page 48 "Illuminance UV Recorder for Windows" Operating Environment Compatible OS Microsoft Windows 7 32/64bit English Microsoft Windows Vista 32bit English Microsoft Windows XP 32bit (SP2 or above) English Memory Capacity Enough memory to stably operate Windows Disc Capacity More than 20 MB free space (More free space is necessary for data) Monitor SVGA (800 ×...
  • Page 49 Fax: +81-263-40-3152 E-mail: support@tandd.com Office Hours: Monday to Friday 9:00-12:00/13:00-17:00 (GMT +9:00 Tokyo Time) [Web Site] http://www.tandd.com/ Illuminance UV Recorder TR-74Ui Introductory Manual Published by T&D CORPORATION © Copyright T&D Corporation. All rights reserved. (2010.08 2nd printing) This is printed on recycled paper.
  • Page 50 Provisions for Free Repair 1. If the Unit does not work properly despite the fact that the customer used it properly and in line with the Introductory Manual, the Unit shall be repaired free of charge through the distributor which sold the Unit. 2.

Table of Contents