Thermo recorder

Advertisement

Quick Links

Thermo Recorder TR7 Series
Please Read First
Package Contents
TR71A
Temperature 2ch
Data Logger
Temperature Sensor
AA Alkaline Battery
TR-0106 x 2
(LR6) x 2
TR72A
Temperature 1ch, Humidity 1ch
Data Logger
Temperature-Humidity
AA Alkaline Battery
Sensor THA-3001
(LR6) x 2
TR72A-S
Temperature 1ch, Humidity 1ch
Data Logger
High Precision
AA Alkaline Battery
Temperature-Humidity
(LR6) x 2
Sensor SHA-3151
TR75A
Thermocouple (K, J, T, E, S, R) Temperature 2ch
Data Logger
AA Alkaline Battery
USB Mini-B Cable
(LR6) x 2
(US-15C)
Part Names
Sensor Jack
Channel 1
Sensor Jack
Channel 2
(TR71A only)
Power Button
Safety Precautions and Instructions
The following items should be strictly obeyed for the safe
usage of this product, and for protecting yourself and other
people from bodily harm and/or damage to property.
Explanation of Symbols
<Warning Symbols>
These entries are actions that absolutely under no
circumstance should be taken. The taking of such an
DANGER
action may cause serious personal physical damage or
death.
These entries are actions that if taken may lead to
CAUTION
physical injury or damage to persons or things.
<Picture Symbols>
Denotes an
Denotes a
important warning
forbidden action.
or caution.
DANGER
To Prevent Serious Accidents
Do not disassemble, repair or modify the unit and/or accesso-
ries.
Do not use the unit in any environment that is exposed to chem-
icals and harmful gases. Doing so may cause corrosion and/or
other danger to the unit. Also, coming in contact with hazardous
substances may cause bodily harm to the user or people nearby.
This product is not water resistant. If water or a foreign object
enters the case, immediately remove batteries and stop using it.
Do not touch the unit or AC adaptor during thunder and light-
ning, as this may cause electrocution.
Do not handle the unit, remove batteries or cables with wet
hands.
This product has been designed for private and/or industrial use
only. It should not be used in situations where strict safety precau-
tions are necessary such as with medical equipment, or in systems
directly or indirectly connected with human life or well-being.
Do not drop or expose the unit to a strong impact.
Do not cut or process the cords for the communication cables.
Also, do not twist, pull on or swing any of the cords.
To prevent damage to the unit from static electricity, remove static
electricity from your body by touching metal around you (such as
a door knob and window frame) before touching the unit.
Place and store the unit and accessories out of the reach of
children.
TR71A / TR72A / TR72A-S / TR75A
USB Mini-B Cable
Manual Set
(US-15C)
(Warranty Included)
USB Mini-B Cable
Manual Set
(US-15C)
(Warranty Included)
(High-Precision Type)
USB Mini-B Cable
Manual Set
(US-15C)
(Warranty Included)
Manual Set
Registration Code
(Warranty Included)
Label
TR71A
TR75A
TR72A
TR72A-S
Thermocouple
Input Terminal
The Introductory Manual also explains operations using the operation buttons.
We are not responsible for any damage, malfunction or trouble,
whether direct or indirect, caused by the use of our product.
Do not use any battery, sensor, or cable other than those speci-
fied by T&D Corporation.
Do not put anything on top of the cable or the unit. This may
cause overheating.
Do not disconnect the USB cable during USB communication.
Doing so may cause adverse effects to the unit and/or PC.
Make sure that sensor and cable plugs are all inserted fully, so
as not to cause an improper connection. Also, when unplugging
the cable from the unit, do not pull the cord, but hold the con-
nector to disconnect.
If the unit produces heat, emits smoke or a strange smell, or
makes unusual noise, immediately remove the batteries and
stop using it. Also, unplug the unit from the PC.
If the unit is not to be used for a long period of time, remove
batteries. Leaving batteries inside the unit may cause battery
leakage and malfunction. Install new batteries when starting or
Denotes an action
re-starting to use a unit.
that should not be
carried out.
For TR75A: Ch.1 and Ch.2 terminals are NOT electrically isolated
from each other. Do not attach non-isolated thermocouple
sensors to objects connected to a live voltage. This may cause a
short circuit or an electrical shock.
CAUTION
» Areas exposed to direct sunlight
» Areas subject to direct flames or heaters, as well as areas in which
hot air accumulates and creates extremely high temperatures
» Areas exposed to static electricity
» Areas exposed to strong magnetic fields
» Areas exposed to water leakage
» Areas subject to condensation or wet areas
» Areas exposed to excessive vibration
» Areas exposed to excessive smoke, dust or dirt.
CAUTION
» There is a risk of fire or explosion if battery is replaced by an incor-
rect type. Use and replace only with correct size and type (AA alka-
line) of battery.
» Do not disassemble, modify, mechanically crush or cut the battery, as
it may cause battery leakage, overheating, explosion or fire.
» Do not dispose of a battery into fire or a hot oven as this can result
in an explosion.
» Do not leave a battery in an extremely high temperature surround-
ing environment or subjected to extremely low air pressure that can
result in an explosion or the leakage of flammable liquid or gas.
CAUTION
» Use the unit in the specified operating environment. Do not use it
for any purpose other than for which it was designed.
» Condensation may occur inside the case when a unit is moved from
one environment to another where there is a great difference in
temperature.
Getting Logger Ready for Installation
Battery Installation & Sensor Connection
Battery
Make sure to use new batteries
(including for replacement) and
insert in the correct direction.
Registration
Code Label
About TR71A Internal Sensor
Channel 1 has an internal temperature sensor. When an external sensor is not connected, the
internal sensor will be used.
About TR75A Input Terminal
When connecting thermocouple wires to the input terminal, make sure that the positive and
Registration
negative connections are in the proper order. If the polarity is incorrect, changes in temperature
Code Label
will be reversed (when the real temperature increases, the measured temperature will decrease).
Wiring Connections
Connect and disconnect the thermocouple wire from the hole
while pressing the input terminal button with a screwdriver or
other such tool.
Do not try to pull out the wire without pressing the button.
Registration
Compatible Wires
Code Label
Single wire:
0.32 to
0.65
Twisted wire: 0.08 to 0.32
Diameter: 0.12
or more
Strip length: 9 to 10
Using GND
If measurements are unstable while using external power (USB or PoE), connect to the GND
terminal.
» See the User's Manual for how to set and check thermocouple sensor type for TR75A.
Operation Buttons
Do not place or store in the following areas:
Precautions for Battery
Other Precautions
TR71A
(AWG 28-22)
(AWG 28-22)
Battery Cover
USB Port
» Do not use the unit in wet areas or places exposed to water such as
bathroom.
» When connecting the unit to your PC, make sure to follow all warn-
ings and directions from your computer manufacturer.
» We shall not guarantee the unit's operation if it has been connected
to a PC using a USB hub or a USB extension cable.
» Do not insert any foreign objects into any of the units' jacks.
» If the unit gets dirty, wipe it with a clean cloth.
» Make sure to remove dust and dirt from plugs of any cables.
» Battery terminals may provide insufficient contact due to age or
vibration. This may lead to data loss.
» Please note that this document has been written based on the pre-
supposition that details about contracts with an Internet provider,
specific network environments and the set-up of any other neces-
sary equipment to enable network connection has already been
taken care of by the User and that connection has been confirmed as
workable. T&D Corporation shall not be responsible for any damages
which a contractor, a user or a third party may suffer, whether direct
or indirect, due to the inability to communicate or use communica-
tion devices.
» Please be careful not to let a third party know of your registration
code. The registration code cannot be reissued or changed.
CAUTION
Notices about Sensors
» Do not connect any sensor to the unit other than those specified by
T&D Corporation.
» Make sure to use sensors within the measurement range indicated
in the specifications for that sensor.
» Do not connect the sensor to any data logger other than those speci-
fied by T&D Corporation.
» Do not expose the sensor to a strong impact. This may adversely
affect measurement accuracy and cause damage or malfunction.
» When the sensor is not to be used for a long period of time, please
store it at normal temperature and humidity.
» The included sensor is not water resistant. If the sensor gets wet, im-
mediately remove the sensor from the unit and wipe it with a clean
cloth as soon as possible. Then allow the sensor to dry in normal
room temperature before using it again.
» Do not use the sensor on the human body.
Temperature-Humidity Sensor
» If extremely severe temperature changes occur, it may result in large
errors in humidity measurement. Once the sensor's temperature
becomes stable, the measurements will return to normal.
» The temperature-humidity sensors will with normal use experience
losses in precision and sensitivity over time due to degradation. If
the sensor is being used in an unsuitable environment (smoky or
dusty places) it may be necessary to change the sensor sooner.
» When using the sensor in an environment where the humidity is
under 30 %RH, the measurements may sometimes fluctuate. This is
not abnormal.
» Do not expose to condensation, dampness, corrosive gases, or
organic solvents.
Thermocouple Sensors
» We do not handle the sale of Thermocouple sensors. Please prepare
a commercially available sensor.
TR72A / TR72A-S
Strip
Button

Advertisement

loading

Summary of Contents for T&D TR75A

  • Page 1 USB Mini-B Cable Manual Set Registration Code (LR6) x 2 (US-15C) (Warranty Included) Label » See the User's Manual for how to set and check thermocouple sensor type for TR75A. Part Names TR71A TR75A TR72A TR72A-S Sensor Jack Channel 1...
  • Page 2 TR71A / TR72A / TR72A-S / TR75A - Specifications TR71A TR72A TR72A-S TR75A Measurement Channels Temperature 2ch Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch Temperature 2ch Sensor Thermistor Thermistor Polymer Resistance Thermistor Polymer Resistance Thermocouple: Type K, J, T, E, S, R (*1) Measurement Units °C,°F...

This manual is also suitable for:

Tr71aTr72aTr72a-sTr7 series