Function
As the antenna passes over the transpon-
der, it energizes the latter with an energy
field of 13.56 MHz. The transponder returns
its code through frequency modulation to
the antenna. An additional coil generates
the positioning pulse. The interpreter which
is integrated within the antenna decodes
the transponder code. A normal reading cy-
cle, including all security checks, is approx-
imately 1 ms.
Mounting Instructions
The transponder has to be mounted on
even ground using a metal screw and a
washer. The maximum fastening torque is
approx. 200 mm
www.goetting.de
HG 70660XA
HG 70660ZA
top view
The system's operability is guaranteed
through fluid, gaseous as well as solid
metal-free materials. However, if mount-
ed directly on or within metal, the tran-
sponder's
reading
influenced.
The
Read-Write
equipped with an EEPROM in which the
code is stored. The EEPROM may be
rewritten up to more than 100,000
times. It has 32 bit available for user da-
ta.
not allowed to exceed 4 Nm. The diameter
of the metal washer should not extend
18 mm.
Screw
Washer
Transponder
approx. 100 mm
35.4 mm
74 mm
distance
is
Transponders
are
Metal-free area
bottom view
HG 70660ZA

Advertisement

loading
Need help?

Need help?

Do you have a question about the HG 70660ZA and is the answer not in the manual?

Questions and answers

Summary of Contents for Gotting HG 70660ZA

  • Page 1 Transponder HG 70660ZA Function As the antenna passes over the transpon- The system’s operability is guaranteed der, it energizes the latter with an energy through fluid, gaseous as well as solid field of 13.56 MHz. The transponder returns metal-free materials. However, if mount-...
  • Page 2 Transponder HG 70660ZA Dimensions and Specifications The maximum reading distance for all tran- As a rule of thumb it can be said that if the sponders can only be achieved when the metal-free area behind the transponder has minimum distance to the metal surface is to be at least of the same range as the maintained.

This manual is also suitable for:

Hg 70660