Battery Memory Set And Call Out - Skyrc Ultimate Duo D260 Instruction Manual

Balance charger / discharger / power supply
Hide thumbs Also See for Ultimate Duo D260:
Table of Contents

Advertisement

The charger can store up to 20 different charge/discharge profiles(each channel 10 sets)
for your convenience, and the stored profiles can be recalled quickly without having to go
through the setup process.
When you are willing to alter the parameter value in the program, press START/ENTER to
make it blink then change the value with INC or DEC. The value will be stored by
pressing START/ENTER once.
Note: All following screen are taking 6S(22.2V) LiPo battery for example.
1. Battery Memory Set
[ B A T T M E M O R Y 1 ]
E N T E R S E T - >
START/ENTER
B A T T T Y P E
L i P o
DEC INC
B A T T V O L T A G E
2 2 . 2 V ( 6 S )
DEC INC
C H A R G E C U R R E N T
5 . 0 A
DEC INC
D I S C H G C U R R E N T
2 . 0 A
DEC INC
D I S C H G V O L T A G E
3 . 0 V / C E L L
DEC INC
T V C = Y O U R R I S K !
4 . 2 0 V
DEC INC
S A V E P R O G R A M
E N T E R
START/ENTER
D260

Battery Memory Set and Call Out

Enter the battery memory program.
(10 different charge/discharge profiles can be stored in each channel).
Set the battery type(LiPo/LiFe/LiIon/LiHV/NiMH/NiCd/Pb).
Set the voltage and number of cells(1S-6S).
Set the charge current(0.1-14.0A).
Set the discharge current (0.1A-2.0A).
Set the discharge voltage(3.0-3.3V/Cell).
Set the terminal voltage(4.18-4.25V).
Press ENTER to save program.
25 ·

Advertisement

Table of Contents
loading

Table of Contents