International comfort products NAHB00101MH Installation Instructions Manual page 3

Condensing gas furnace conversion
Table of Contents

Advertisement

Figure 1
Securing Furnace to Structure
RETURN AIR PLENUM
(WHEN USED)
ATTACH
ADHESIVE
POUCH TO
DOOR
OR SIDE
FURNACE
COIL
CASING
WHEN COIL CASING IS NOT INSTALLED (NOT SHOWN)
1. Accessory floor base MUST be used. Review floor base
Installation Instructions before installation.
2. Secure accessory floor base to structure using 5/16−in.
(8 mm) lag screws.
3. Fasten furnace to accessory floor base using No.10 self
tapping screws through tabs on both sides of base (two
each side).
Procedure 2 — Replace Gas Valve
CAUTION
!
UNIT OPERATION HAZARD
Failure to follow this caution may result in unit damage or
improper operation.
Label all wires prior to disconnection when servicing controls.
443 06 4003 00
WALL STUDS
NOTE: USE 5/16-IN. (8 MM) LAG SCREWS WHEN
SECURING TO STRUCTURE WALLS AND FLOOR.
USE NO. 10 SELF-TAPPING SCREWS WHEN FASTENING
TO SHEET METAL.
D'EQUIPEMENT D'OPERATION
Toute erreur de câblage peut être une source de danger et
de panne.
Lors des opérations d'entretien des commandes, étiqueter
tous les fils avant de les déconnecter.
FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury,
death or property damage.
Gas supply MUST be shut off before disconnecting electrical
power and proceeding with conversion.
Specifications subject to change without notice.
SECURE FURNACE TO STRUCTURE
PIPE STRAP-REMOVE SLACK
(TYPICAL BOTH SIDES)
OR
1/8-IN. (7 MM) THICK ANGLE
MOUNTING
BRACKET (TYPICAL BOTH SIDES)
FASTEN FURNACE TO CASING
SCREWS THROUGH
CASING FLANGES
OR
PIPE STRAP FASTENED TO
FURNACE AND COIL CASING SIDES
(TYPICAL BOTH SIDES)
1-IN. (25 MM) MAXIMUM
SECURE COIL CASING TO FLOOR
LAG SCREWS THROUGH COIL CASING
FLANGE (TYPICAL BOTH SIDE)
OR
ANGLE BRACKET OR PIPE STRAP
PRUDENCE
!
WARNING
!
A11492
3

Advertisement

Table of Contents
loading

Table of Contents