Download Print this page
International comfort products NTC7050BFG1 Technical Manual
International comfort products NTC7050BFG1 Technical Manual

International comfort products NTC7050BFG1 Technical Manual

Advertisement

Quick Links

Design Certified
by A.G.A.
Printed in U.S.A.
Save This Manual For Future Reference
Models
NTC7050BFG1 / GNL050N12G1
NTC7075BFG1 / GNL075N12G1
NTC7100BHG1 / GNL100N16G1
NTC7125BKG1 / GNL125N20G1
NDC7050BFG1 / GDL050N12G1
NDC7075BFG1 / GDL075N12G1
NDC7100BHG1 / GDL100N16G1
NDC7125BKG1 / GDL125N20G1
Manufactured by:
International Comfort Products Corporation (USA)
Lewisburg, TN USA 37091
LP1
APPROVED
R
5/16/2001
441 03 2009 00

Advertisement

loading

Summary of Contents for International comfort products NTC7050BFG1

  • Page 1 NTC7125BKG1 / GNL125N20G1 NDC7050BFG1 / GDL050N12G1 NDC7075BFG1 / GDL075N12G1 NDC7100BHG1 / GDL100N16G1 NDC7125BKG1 / GDL125N20G1 Manufactured by: International Comfort Products Corporation (USA) Lewisburg, TN USA 37091 APPROVED Design Certified Save This Manual For Future Reference by A.G.A. Printed in U.S.A.
  • Page 2 Manufacturers Number (Mfr No - -See Rating Plate) ALL Models Specifications General Gas Type Transformer Size (VA) T’stat Heat Anticipator Gas & Ignition Gas Valve HW SV9504 HW SV9504 Regulation Type SNAP SNAP Manifold Press. (² WC) 10.0 Pilot Orifice Size .018 .011 Ignition Type/Series...
  • Page 3 Specifications NTC7125BKG NDC7050BFG NDC7075BFG GNL125N20G GDL050N12G GDL075N12G General Input (Btuh) 125,000 50,000 75,000 Output (Btuh) 100,000 40,000 60,000 ° Temp. Rise ( 45--75 35--65 35--65 Electrical (Volts/Hz/FLA) 115/60/10.5 115/60/5.3 115/60/7.5 Gas & Ignition Gas Type Std. Main Orifices (No/Size) 5/#42 5/#54 2/#42 2/#54...
  • Page 4 Specifications NDC7100BHG NDC7125BKG GDL100N16G GDL125N20G General Input (Btuh) 100,000 125,000 Output (Btuh) 80,000 100,000 ° Temp. Rise ( 35--65 45--75 Electrical (Volts/Hz/FLA) 115/60/9.2 115/60/10.5 Gas & Ignition Gas Type Std. Main Orifices (No/Size) 4/#42 4/#54 5/#42 5/#54 Combustion Std. Pressure (² of WC) Blower Burner Box Differential...
  • Page 5 NTC7075BFG/GNL075N12G & NDC7075BFG/GDL075N12G Air Delivery in Cubic Feet per Minute (C.F.M.) Air Delivery in Liters Per Second (L/S) (Furnace Rated @0.5² ² ² ² WC ESP) (Furnace Rated @0.5² ² ² ² WC ESP) MED L MED H HIGH MED L MED H HIGH ----...
  • Page 6: Wiring Diagram

    1. Wiring Diagram 441 03 2009 00 THIS DATA SUBJECT TO CHANGE WITHOUT NOTICE...
  • Page 7 NTC7 / GNL MODELS 25- -21- -72a 441 03 2009 00 THIS DATA SUBJECT TO CHANGE WITHOUT NOTICE...
  • Page 8 Replacement Parts - NTC7/GNL Models -- NTC7050BFG1/GNL050N12G1, NTC7075BFG1/GNL075N12G1, NTC7100BHG1/GNL100N16G1, NTC7125BKG1/GNL125N20G1 Replacement part supplied will be current active part. For parts not listed, consult place of purchase. NTC7/GNL NTC7/GNL Functional Parts Functional Parts Part Part Non- Functional Parts Non- Functional Parts...
  • Page 9 NDC7 / GDL MODELS 25- -21- -73 441 03 2009 00...
  • Page 10 Replacement Parts - NDC7/GDL Models -- NDC7050BFG1/GDL050N12G1, NDC7075BFG1/GDL075N12G1, NDC7100BHG1/GDL100N16G1, NDC7125BKG1/GDL125N20G1 (Natural Gas) Replacement part supplied will be current active part. For parts not listed, consult place of purchase. NDC7/GDL NDC7/GDL Functional Parts Functional Parts Part Part Non- Functional Parts Non- Functional Parts Part Part Description...
  • Page 11 Replacement Parts - NDC7/GDL Models -- NDC7050BFG1/GDL050N12G1, NDC7075BFG1/GDL075N12G1, NDC7100BHG1/GDL100N16G1, NDC7125BKG1/GDL125N20G1 (Natural Gas) Replacement part supplied will be current active part. For parts not listed, consult place of purchase. NDC7/GDL Non- Functional Parts Non- Functional Parts Part Part Description Number Clamp, Capacitor 1095020 Filter, Air 16²...