Introduction
Thank
you
for
purchasing
the
User Guide to understand and ensure safe, proper, effective and
responsible use of the Hurricane CL.
Safety Precautions
Please
ensure
you
have
read
precautions
before
operating
this
instructions please refer to the supplementary on-line user manual
(www.hurricane-es.com).
Instructions for use of this product will vary depending on chemical applications.
Always read the product label when preparing your solution.
Always comply with any requirements for Personal Protective Equipment
(PPE) as required by the formulation label.
This appliance is to be kept out of reach from children. However, it can be
used by children aged 8 years and above, as well as persons with reduced
physical, sensory or mental capacities or lack of experience and knowledge,
provided they have been given supervision or instruction concerning use of
the appliance in a safe way, and understand the hazards involved.
Children should not play with the appliance, and cleaning and user
maintenance should not be made by children without supervision.
Children should be supervised to ensure they do not play with the appliance.
Users should hold the appliance and manually cover the designated fogging
areas.
The fogger should not be left operating unattended, and for the most efficient
application it should not be left stationary.
This fogger can be used with water-based, oil-based, and solvent-based
formulations.
Never direct fogging at live electrical items, animals, humans, etc. Remember
to cover aquariums before fogging takes place.
Ensure you are wearing appropriate PPE when operating this fogger.
Do not use a fogger that is broken or damaged in any way. Do not alter the
fogger by adding or removing parts.
Do not restrict the motor blower air intake area.
Please take note of the below diagram to familiarise yourself with the design and
structure of the unit:
THREE (3) PRECISION
NOZZLES FOR GREATER
OUTPUT CAPACITY
STAINLESS STEEL
PRECISION METERING
VALVE WITH FILTER
TRANSLUCENT
CORROSION
AND IMPACT
RESISTANT
TANK
Formulation
Always read the product label when preparing your solution and ensure the
formulation is suitable for the intended application.
This fogger can be used with water-based, oil-based, and solvent-based
formulations. Ensure that formulation is applied only in strict compliance
with the formulation label and store formulation in its original labelled
container.
Remove the filling cap to pour formulation into the tank. Add only premixed/
diluted formulations to the tank.
Pelsis UK Contact Number: +44 (0) 800 988 5359
USER GUIDE
Pelsis Belgium Contact Number: +32 (0) 3 886 22 11
CL
Hurricane
CL.
Please
read
and
fully
understood
the
appliance. For
further
in
CARRYING HANDLE
ON/OFF SWITCH
WITH LIGHT
AIR INTAKE AREA
ADJUSTABLE
LOCKING DEVICE
REMOVABLE FILLING
CAP WITH TETHER
Operation
With the fogger power off, remove the filling cap and pour your premixed
formulation into the tank, up to a maximum 3.8 litres, and replace the cap.
Ensuring the fogger is pointing in a safe direction, turn on via the power
switch and select the appropriate flow valve setting.
The exact method of operation is dependent on a number of factors,
this
including the application, flow rate, formulation viscosity, but best results
are normally achieved maintaining a distance of 1-4 metres from the items
you want to fog. Keep moving the fogger with slow, steady movements for
an even coverage, starting from the highest point. If there is liquid run-off
then the application is too heavy, either move further away, adjust the flow
safety
rate or speed up.
depth
Do not allow the fogger to operate unattended. Do not stand in water or hold
over water while operating fogger and do not allow the unit to be submersed
in water. Do not use outdoors when it's raining.
Do not block the air intake area.
Flow Rate Information
Please use the below table as a reference for the flow rate of the Hurricane CL.
Metering
Valve
Setting
#1
#2
#3
Thicker viscosity liquids will flow at lower rates than demonstrated in the
above table, and produce a bigger droplet size.
Adjusting the valve will regulate flow rate.
When the valve is turned clockwise, flow rate will reduce; when turned anti-
clockwise, flow rate will increase.
After Use
Turn the flow valve to the OFF position after each fogging application while
the motor is still operating to allow the clearing of the lines.
Turn off the appliance before disconnecting the battery power supply. Do not
turn off the fogger or the battery power supply with wet hands.
Clean the Air Intake Filter after each application. If the filter becomes saturat-
ed while the fogger is in operation, switch it off and clean the filter.
Formulation should not be stored in the tank. The tank should be cleaned af-
ter each use with hot water with a detergent solution and flushed thoroughly
with clean water before reuse. To ensure a full flush, fully open the valve and
operate the fogger for 3 to 5 minutes.
Hurricane External Battery System
Safety
This battery is specifically designed for the Pelsis Limited Hurricane CL Fogger. Do not
try to use this battery on other products or systems. The battery must be protected at
all times from moisture/water damage. Ensure all cabling is free from nicks, cracks,
and other signs of abuse, however, if found, do not use the appliance and contact
your supplier for repair.
To keep this product safe please:
Store in a cool environment or at room temperature. When possible, charge the
battery at room temperature, keeping the charger in a cool, ventilated area when in
a warm climate. Store the battery fully charged when left idle for longer than a 30-
day period. Do not open the battery pack or attempt to repair and never connect the
Hurricane CL to the mains.
Pelsis Ltd
Sterling House, Grimbald Crag Close,
Knaresborough, HG5 8PJ, UK
Hurricane Flow Rate And Droplet Size
Flow Rate
Droplet Size
Microns - Volume
mL/Min
Median Diameter
60
80 MICRONS
90
80 MICRONS
120
80 MICRONS
Pelsis Belgium NV
Industrieweg 15, 2880
Bornem, Belgium

Advertisement

loading

Summary of Contents for Pelsis CURTIS DYNA-FOG HURRICANE CL

  • Page 1 Hurricane External Battery System AIR INTAKE AREA Safety This battery is specifically designed for the Pelsis Limited Hurricane CL Fogger. Do not ADJUSTABLE try to use this battery on other products or systems. The battery must be protected at LOCKING DEVICE all times from moisture/water damage.
  • Page 2 Features otherwise arise from inappropriate waste handling. Your new battery pack has been designed to power the Pelsis Limited Hurricane CL Please contact your local authority for further details of your nearest designated Fogger.