Thermo Pride CMA4-50D36N Installation And Service Manual page 39

Gas fired high efficiency furnace
Table of Contents

Advertisement

ALTERATIONS REQ'D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE
COOLING UNIT
24,000
30,000
36,000
Speed Tap \
Static
Pressure
0.1
Low
836
ML
1044
MH
1250
High
1339
Speed Tap \
Static
Pressure
0.1
Low
53
ML
42
MH
35
High
31
Speed Tap
Blower Motor Current Draw (Amps) vs. External Static pressure (in. WC.)
\ Static
0.1
Pressure
Low
3.3
ML
4.0
MH
4.6
High
5.3
Speed Tap \
Static
Pressure
0.1
Low
315
ML
400
MH
485
573
High
CMA4-50D36
HTG Speed
LOW
LOW
LOW
Furnace Airflow (CFM) vs. External Static pressure (in. WC.)
0.2
0.3
805
773
1010
972
1196
1146
1338
1283
Temperature Rise vs. External Static Pressure (in. WC.)
0.2
0.3
55
57
44
45
37
38
33
34
0.2
0.3
3.2
3.1
3.8
3.6
4.4
4.2
5.1
5.0
Blower Motor Watts vs. External Static pressure (in. WC.)
0.2
0.3
311
304
390
376
467
452
555
544
=
Recommended operation range
34
Recommended CLG Speed
MED-LOW
MED-HIGH
HIGH
0.4
0.5
743
695
620
914
860
826
1101
1038
977
1233
1162
1086
0.4
0.5
59
63
48
51
40
42
36
38
0.4
0.5
0.6
3.0
2.9
2.7
3.5
3.4
3.2
4.1
4.0
3.8
4.9
4.7
4.6
0.4
0.5
300
292
281
363
351
342
441
427
412
530
513
493
0.6
0.7
566
752
902
1008
0.6
0.7
71
78
53
59
45
49
41
44
0.7
2.6
3.1
3.6
4.4
0.6
0.7
275
330
394
477

Hide quick links: