Whynter ARC-122DS Instruction Manual

Whynter ARC-122DS Instruction Manual

Elite 12,000 btu dual hose digital portable air conditioner
Hide thumbs Also See for ARC-122DS:

Advertisement

Quick Links

WHYNTER ELITE 12,000 BTU DUAL HOSE DIGITAL PORTABLE
AIR CONDITIONER
Model # : ARC-122D$
INSTRUCTION MANUAL
Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before
using this product. Keep this manual in a safe place for future reference.

Advertisement

Table of Contents
loading

Summary of Contents for Whynter ARC-122DS

  • Page 1 WHYNTER ELITE 12,000 BTU DUAL HOSE DIGITAL PORTABLE AIR CONDITIONER Model # : ARC-122D$ INSTRUCTION MANUAL Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before using this product. Keep this manual in a safe place for future reference.
  • Page 2 4 - 6 8 - 9 11 - 12 13 - 14 17 - 18...
  • Page 3: Disposal Information

    Please follow the instructions provided in this user guide to obtain the very best performance from your portable air conditioner and take full advantage of the many features your portable air condi­ tioner offers you. We trust that your Whynter air conditioner will provide the performance and relia­ bility that we stand for.
  • Page 4: Safety Precautions

    SAFETY PRECAUTIONS TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY WARNING WHEN USING YOUR AIR CONDIITIONER, FOLLOW THESE BASIC PRECAUTIONS: Before the appliance is used, it must be properly positioned and installed as detailed in this manual. • Do not under any circumstances cut or remove the third (ground) prong from the power cord •...
  • Page 5 Only install and operate this appliance as outlined in this instruction manual. At all times,use care when using this appliance. Do not modify this appliance in any way to avoid danger. Electrical equipment and installations regulated by national legislation must be followed. Children must not use this appliance unsupervised.
  • Page 6 Stagnation of possible leaks of refrigerant gas in unventilated rooms could lead to fire or an explosion hazard should the refrigerant come in contact with electric heaters, stoves or other sources of ignition. Use car when storing the appliance to prevent mechanical faults. Only persons authorised by an accredited agency certifying their competence to handle refrigerants in compliance with sector legislation should work on refrigerant circuits.
  • Page 7 Cooling Capacity: 12,000 BTU (SACC 7,000 BTU) Large Exhaust Hose: 5.9" diameter Large Hose Connector: 5.9" diameter with 5.0" diameter reducer Small Intake Hose: 5.0" diameter Small Hose Connector: 5.0" diameter Fixture and Window Kit: 5.0" diameter Window Kit: 6.5" W x 20" (min)/ 46" (max) L...
  • Page 8 Front Air Vent/ Louvers Control Panel Handle Casters (four) Air Filter Air Intake Air Exhaust (large hose) Air Intake (small hose) Power Cord Lower Drain Port...
  • Page 9 ** The fixture pieces may come attached to the cover pieces. To remove, twist the cover pieces to allow the tab from the fixtures to disengage from the covers, and twist the covers to remove from the fixtures. • Note: Please visit whynter.com for optional accessories information...
  • Page 10: Control Panel

    CONTROL PANEL LCD Display ° ! �� Power Button Mode Control -<'.1::1 � Fan Speed 088h.-lfilge] Timer Button Button [�]CJ Warning Light Timer/Temp Set Control ., - Indication symbols on LCD ,:j � Cooling mode High Fan speed "II' c::1j Dehumidifying mode Medium Fan speed Fan only mode...
  • Page 11: Installation

    WARNING: NEVER OPERATE THE AIR CONDITIONER WITHOUT THE AIR FILTER Fig. 1a Your Whynter portable air conditioner is equipped with a washable Pre-Filter and an Activated Carbon Filter. The washable Pre-Filter removes large particles such as dust, pet hair and dander.
  • Page 12 9' long. If you are interested in purchasing an additional 5' exhaust hose, please contact support@whynter.com for retail sales information or visit www.whynter.com for a list of optional accessories. Note: To remove the hose(s) from the unit, press the release button and slide the hose and connector out.
  • Page 13 OPERATION INSTRUCTIONS BEFORE USING YOUR APPLIANCE • Remove the exterior and interior packaging • Before connecting the appliance to a power source and operating, let the unit stand upright for a minimum of 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation. SWITCHING ON/OFF THE AIR CONDITIONER The appliance can be switched ON or OFF by pressing the POWER button on the control panel or the ON/OFF but­...
  • Page 14 OPERATION INSTRUCTIONS TIMER (DELAYED SWITCH ON/ OFF) FUNCTION This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) de­ lay can be set, enabled and disabled. The timer is adjustable between 1 - 24 hours. SETTING SWITCH OFF TIMER With the air conditioner operating in any function mode, press the Timer button.
  • Page 15: Remote Control

    REMOTE CONTROL The portable air conditioner can be switched on by the remote control. To transmit signals from the remote con­ trol to the air conditioner, point the front part of the remote handset towards the control panel on the air condi­ tioner.
  • Page 16: Care And Maintenance

    To remove the hose connectors from the fixtures on the window kit, slightly turn, push and gently pull the connector to release. Otherwise, remove the window kit from the window opening. • Place the storage cover over the air conditioner. NOTE: Please contact Whynter at support@whynter.com for additional internal maintenance cleaning instructions.