Durapac PHS-1900 Instruction Manual

Durapac PHS-1900 Instruction Manual

Single acting, single speed hydrostatic hand pump

Advertisement

Quick Links

Instruction Manual
Single Acting, Single Speed Hydrostatic Hand
Pump – PHS-1900
Maximum Operating Pressure – 700 bar
ABSOLUTE EQUIPMENT PTY LTD – 2/186 Granite Street, GEEBUNG QLD 4034 – Australia
sales@absoluteequipment.com.au
– Phone:
+61 7 3865 4006
– Fax:
+61 7 3102 6288

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PHS-1900 and is the answer not in the manual?

Questions and answers

Summary of Contents for Durapac PHS-1900

  • Page 1 Instruction Manual Single Acting, Single Speed Hydrostatic Hand Pump – PHS-1900 Maximum Operating Pressure – 700 bar ABSOLUTE EQUIPMENT PTY LTD – 2/186 Granite Street, GEEBUNG QLD 4034 – Australia sales@absoluteequipment.com.au – Phone: +61 7 3865 4006 – Fax: +61 7 3102 6288...
  • Page 2: Product Information

    The user must ultimately make the decision regarding suitability of the product for any given task and assume the responsibility of safety for all in the work area. Contact a Durapac representative if you are unsure of your pumps suitability for a particular application.
  • Page 3  Hydraulic equipment must only be serviced by a qualified hydraulic technician. For repair service, contact the Durapac authorised service centre in your area. To protect your warranty, use only high quality hydraulic fluid CAUTION: ...
  • Page 4: Hydraulic Pumps

     Do NOT subject the pump and its components to shock loads  Use only Durapac approved accessories and components  Do NOT connect to an application which can return more fluid to the reservoir than the pump reservoir can hold ...
  • Page 5: Operation

    4.1 Familiarise yourself with the specifications and illustrations in this owner’s manual. Know your pump, its limitations and how it operates before attempting to use. Refer to the specification chart below or if in doubt, contact a Durapac representative. Used...
  • Page 6: Pressure Relief Valve

    Durapac authorised service centre  Damage to hydraulic hoses may not be detected during visual inspections. For this reason, Durapac recommends that hydraulic hoses be replaced on a regular basis  Tighten connections as needed. Use non-hardening pipe thread compound when servicing connections Dirt, sand, etc.
  • Page 7: Bleeding Air From The System

    When not in use, depressurise and disconnect the hydraulic pump from the application. 6.5.2 Wipe clean thoroughly and store in a clean, dry environment. Avoid temperature extremes. 6.5.3 Shield pump with a protective cover. PHS-1900 Hydrostatic Pump - V1.0 www.durapac.com Page 7 of 7...
  • Page 8: Troubleshooting

    Send to a Durapac authorised springs service centre for repair  Internally damaged cylinder Send to a Durapac authorised service centre for repair  Pump reservoir too full Drain fluid to correct level PHS-1900 Hydrostatic Pump - V1.0 www.durapac.com Page 8 of 8...
  • Page 9: Parts Breakdown And List

    ZAM1586 1 14 Bolt ZAM1573 1 Items marked with a * are contained within a standard Repair Kit. Serial number, model and part number need to be quoted when ordering parts. PHS-1900 Hydrostatic Pump - V1.0 www.durapac.com Page 9 of 9...

Table of Contents