Replacing An Optimizer - Huawei SUN2000 User Manual

Smart pv optimizer
Hide thumbs Also See for SUN2000:
Table of Contents

Advertisement

SUN2000 Smart PV Optimizer
User Manual

4.5 Replacing an Optimizer

Prerequisites
Procedure
Step 1 Put on the protective gloves.
Step 2 Power off the inverter.
Step 3 Disconnect the input terminals of the optimizer.
Step 4 Remove the old optimizer.
1.
2.
Step 5 Install a new optimizer.
1.
2.
Step 6 Power on the inverter. On the Device Commissioning screen, choose
Maintenance > Subdevice management, and tap Auto search to add the new
optimizer.
Issue 01 (2021-10-30)
NO TE
Contact the service provider if all suggested measures listed above are completed and the
fault still exists.
Use dedicated insulation tools, and wear insulation shoes and protective
gloves before performing operations.
A new smart PV optimizer is available.
Record the cable connection positions on the optimizer and disconnect the
cables.
Loosen the bolt that secures the optimizer and remove the optimizer.
Secure the new optimizer to the corresponding bolt and tighten the bolt.
Connect the cables to the new optimizer based on the recorded information.
NO TE
If multiple optimizers need to be replaced, record the mapping information.
Copyright © Huawei Technologies Co., Ltd.
4 System Maintenance
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sun2000-600w-pSun2000-450w-pSun2000-450w-p2

Table of Contents