Comp to Aux Temp Delta The minimum difference between the
d
current temperature and the set temperature that will activate this
stage (regardless if the maximum run time of the previous stage
was reached). Options are Auto (default), Disabled, and 1 to 10°
F (0.6 to 5.6° C).
Cool Min On Time Sets the minimum equipment run time in
d
cool mode: 1 to 20 min (default is 5 min).
Heat Min On Time Sets the minimum equipment run time in
d
heat mode: 1 to 20 min (default is 5 min).
Temp Correction
Lets you program an offset between the real temperature at thermostat
and the displayed temperature. If you find that the temperature where the
thermostat is located does not represent the room temperature, change the
offset to compensate for the difference. The correct temperature is
adjustable from +/- 10° F in 0.5° F (0.3° C) increments.
Installer Code
To prevent accidental modifications to the installation settings, you can
enable a 4- digit installer code. This code is pre- programmed to 3262.

Test Equipment

These options let you test the wiring and connections of the devices
connected to the thermostat by turning them on or off.
The equipment will turn off when you exit the menu.
EQUIPMENT DAMAGE HAZARD
This feature is intended for professional installers only.
Incorrect configuration may lead to improper operation and
equipment damage.
Failure to follow this warning could result in equipment
damage.
Compressor protection and minimum run- time features are not
enforced while in this mode.