Cool Dissipation Time The amount of time the fan will run after
d
the cool has been turned off. Running the fan for a period of time
allows for any cooled air left in the ducts to circulate throughout
the home. The time is adjustable from 0 to 900 seconds. The de-
fault value is 30 seconds.
Advanced Settings
Your Carrier thermostat is preconfigured for the most common system
type. The advanced settings and configuration options detailed in this
section are intended for professional installers only. Incorrect
configuration may lead to improper operation and equipment damage.
These options customize how long each stage will run before the next
stage turns on. You may also program when a particular stage is turned
on based on the temperature delta between the set temperature and the
current temperature.
Reverse Staging If enabled, the thermostat will cycle down from
d
the higher stages so that when it approaches set point it will only
be running in stage 1. The thermostat calculates which stage to
start the HVAC equipment in depending on the indoor tempera-
ture and set point temperature delta. The HVAC equipment will
start in stage 1. As the stage 1 temperature delta is exceeded, the
second stage will engage. Once the equipment has brought the
current temperature back to within the heat or cool differential
setting, stage 2 will disengage and stage 1 will remain running
until the set point is met.
Stage 2 Temp Delta The minimum difference between the cur-
d
rent temperature and the set temperature that will activate the
auxiliary heat (regardless if the maximum run time of the previ-
ous stage was reached). Options are Auto (default) and 1 to 10° F
(0.6 to 5.6° C).
Stage 1 Max Runtime The maximum amount of time stage 1
d
will run before engaging the next stage. Options are Auto (de-
fault) and 10 to 120 minutes.
Comp to Aux Runtime The maximum amount of time this stage
d
will run before engaging the next stage. Options are Auto (de-
fault) and 1 to 10° F (0.6 to 5.6° C).