Advertisement

Quick Links

INSTALLATION AND OPERATING INSTRUCTIONS
for all Hydrocarbon
VSP Models
809-169A REV B 10/29/2020
SEE BACK COVER FOR
3779 CHAMPION BLVD, WINSTON-SALEM, NC 27105
WARRANTY REGISTRATION
Phone: (888) 845-9800 | Fax: (800) 253-5168 | Web: victoryrefrigeration.com

Advertisement

Table of Contents
loading

Summary of Contents for Victory VSP27HC

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS for all Hydrocarbon VSP Models 809-169A REV B 10/29/2020 SEE BACK COVER FOR 3779 CHAMPION BLVD, WINSTON-SALEM, NC 27105 WARRANTY REGISTRATION Phone: (888) 845-9800 | Fax: (800) 253-5168 | Web: victoryrefrigeration.com...
  • Page 2: Table Of Contents

    From the earliest stages of production design, to focused steps in fabrication and assembly, rigid standards of We thank you for your choice and confidence in Victory quality are maintained by our staff of skilled employees. Equipment.
  • Page 3: Safety

    R290 equipment. • Clean a dirty condenser with a sharp object. • Use ONLY Victory factory service parts. Use of non • Store gasoline, kerosene or any other flammable OEM parts can be dangerous because of the design material near the cabinet.
  • Page 4: Important Information

    WARM AIR OUT Agency Approvals These marks appear on the dataplate or serial tag, located in the inside of the left wall. The dataplate also contains the model and serial numbers as well as electrical requirements. Victory Refrigeration Rev. 10/20...
  • Page 5: Product Information

    Door Count Drawers Power Cord w x d x h (Inches) Amps Charge g /Charge oz VSP27HC 27 x 32 7/8 x 51 1/8 R-290/50/1.76 VSPD27HC 27 x 32 5/8 x 51 1/8 VSP32HC 32 x 32 x 45 1/8...
  • Page 6: Clearance And Placement

    Ventilation: Grille area at front must be free and clear of any object or wall. • Power Outlet: The installation of this appliance requires a dedicated power outlet located within the length of the unit's power cord and be accessible for the purpose to disconnect power. Victory Refrigeration Rev. 10/20...
  • Page 7: Unpacking And Set Up

    5. Once the caster or leg cannot be turned any further, use a 3/4 inch wrench to tighten the nut in between the mounting plate and the wheel of the caster until snug. Rev. 10/20 Victory Refrigeration...
  • Page 8: Leveling

    Do NOT loosen casters to level the cabinet. Casters MUST be CAUTION tightly secured to cabinet for full strength. Install or attach any accessories that will be used Remove any plastic covering the stainless steel. Victory Refrigeration Rev. 10/20...
  • Page 9: Shelf Installation

    4. Install all remaining clips. manner. Contact Victory customer service if fewer shelves or a different configuration to ensure shelf 5. Install shelves onto clips with the product retention overloading will not occur.
  • Page 10: Drawer Maintenance

    8. Align the drawer slide members and moving slide members 9. Slide the drawer in and lock the slide by pushing the front of the locking tab down and in Victory Refrigeration Rev. 10/20...
  • Page 11: Electrical

    38º F. Cautions Care must be taken whenever moving or servicing the unit. The refrigerant is contained in a sealed system, but if released it is flammable. Rev. 10/20 Victory Refrigeration...
  • Page 12: Door Reversal Instructions

    9. Install the handle on what is now the top of the door 10. Slide door back into position and gently lower into the white pivot cam 11. Replace hinge cover Victory Refrigeration Rev. 10/20...
  • Page 13: Using The Unit

    Close door, if message does not change, call for service. Compressor run time too long Check doors or drawers closed. If yes, call for service. E01, E02, E03, E04 Sensor unplugged or has failed Call for service. Rev. 10/20 Victory Refrigeration...
  • Page 14: Sequence Of Operations Refrigerator

    The incoming power, not in, the Evaporator through the controller. Evaporator Fan will run. through the controller. Fan will run. Condition Cabinet Temp > Set point + 2 Cabinet Temperature <= Set point - 2 Defrost Victory Refrigeration Rev. 10/20...
  • Page 15 • Toggles display °F/°C Note: When the controller is in a Standby Mode, a blue dot will be displayed as shown here. To switch out of Standby Mode, push and hold the Defrost button until the display reads ON. Rev. 10/20 Victory Refrigeration...
  • Page 16 The alarm condition is always signaled by the alarm icon . To turn off the relative icon will continue flashing. NOTE: If alarm exclusion times are in progress (ALA folder of the parameter table), the alarm is not signaled. Victory Refrigeration Rev. 10/20...
  • Page 17 Blink "S03 ". lf configured: cut in alarm relay, beep "S3" sensor failure the buzzer (short or open) "E04" "S1" error Always Blink "SO4 ". lf configured: cut in alarm relay, beep "S4" sensor failure the buzzer (short or open) How to Acknowledge Alarms Rev. 10/20 Victory Refrigeration...
  • Page 18: Cleaning And Maintenance

    8. Return food to the unit when it has reached a safe temperature. 4. Scrub all interior surfaces and door gaskets with a warm (100 F to 110 F) detergent solution and a soft Pan Support Note Victory Refrigeration Rev. 10/20...
  • Page 19: Condenser Cleaning

    2. Remove the Phillips head screws at the top of the panel. 3. Once the screws have been removed the you can lower the panel. Please note the electrical cord will still be connected to the panel. Rev. 10/20 Victory Refrigeration...
  • Page 20: Methods For Cleaning Stainless Steel

    Swab or soak with cloth. Let Effective on tenacious deposits and Scale 10% phosphoric acid, or Dilac, Oakite stand 10-15 minutes. Always or where scale No. 33, Texo 12, Texo N.Y. follow with neutralizer rinse, has built up. and dry. Victory Refrigeration Rev. 10/20...
  • Page 21: Help

    Unit cools but turns on and off frequently Have system checked defective Refrigeration issue Check tubing for routing Check for loose Tubing rattle Loose parts components Replace fan blade Makes excessive noise Bent or broken fan blade Noisy fan motor Replace fan motor Rev. 10/20 Victory Refrigeration...
  • Page 22: For The Service Tech

    A sign noting service of a system containing propane must be attached to the unit during refrigeration service. • A combustible gas leak detector must be used to inform anyone in the area when propane is present in the air. Victory Refrigeration Rev. 10/20...
  • Page 23: For The Service Tech - Wiring Diagram

    *NOT ALL MODELS* CONDENSER FAN CURRENT RELAY S.C. COMP LEGEND RC - RUN CAPACITOR SC - START CAPACITOR OL - OVERLOAD COMPRESSOR DETAIL SOME MODELS - DANFOSS CONTROLLER TERMINAL - CONNECTION POINT - CONTROL RELAY DANFOSS CONTROLLER DETAIL Rev. 10/20 Victory Refrigeration...
  • Page 24: Limited Warranty

    Victory® Refrigeration (Victory) warrants to the original purchaser of Victory branded equipment, that Proof of purchase must be supplied to Victory to validate such equipment is free from defects in material and the warranty. This warranty is valid only if equipment is workmanship, under normal use, proper maintenance and properly installed, and started-up as outlined in the Owner’s...
  • Page 25: Limited Warranty (Continued)

    LIMITATION OF LIABILITY: that requires extra work, and/or travel, to gain access to the Victory or its affiliates shall not be liable for any indirect, unit for service is the sole responsibility of the equipment incidental, special or consequential damages, or losses of a purchaser.
  • Page 26 User Manual for VSP Victory Warranty Registration Register your product online at Victory.com/parts-service or fill out and mail the form below. Cabinet Model Number: _____________________________________________ Date Of Installation: _________________ Cabinet Serial Number: _____________________________________________ Location Of Product Business Name: ____________________________________________________ Business Street: ____________________________________________________...

Table of Contents