IME Siretta SNYPER-LTEM User Manual

IME Siretta SNYPER-LTEM User Manual

Global lte cat m, lte cat nb iot & 2g / gsm cellular signal & network analyser

Advertisement

Quick Links

www.ime.de
SNYPER-LTEM (GL)
Global LTE Cat M, LTE Cat NB IoT & 2G /
GSM Cellular Signal & Network Analyser
User Manual
Rev 1.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Siretta SNYPER-LTEM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IME Siretta SNYPER-LTEM

  • Page 1 SNYPER-LTEM (GL) Global LTE Cat M, LTE Cat NB IoT & 2G / GSM Cellular Signal & Network Analyser User Manual Rev 1.1...
  • Page 2: Table Of Contents

    SNYPER-LTEM (GL) User Manual Table of Contents Page Introduction Overview What’s in the Box? Features Specifications Operating Frequencies Detail Product Images First Time Use of the SNYPER-LTEM (GL) Charging and Battery Status Main Menu Saved Results Menu Survey Menu...
  • Page 3: Introduction

    SNYPER-LTEM (GL) User Manual Introduction This document explains the operation of, and technical characteristics of the SNYPER-LTEM (GL). The SNYPER-LTEM (GL) is a high performance, multi-language network signal analyser dedicated to surveying the LTE Cat M, LTE Cat NB IoT & 2G / GSM Global networks.
  • Page 4: Overview

    SNYPER-LTEM (GL) User Manual Overview What’s in the Box? SNYPER-LTEM PSU with 4 Adapter Heads Blue Antenna - General Purpose LTE (4G) & GPRS (2G) USB Cable USB Car Charger Quick Start Guide Figure 1. SNYPER-LTEM (GL) case contents...
  • Page 5: Features

    SNYPER-LTEM (GL) User Manual Features The SNYPER-LTEM (GL) is a high performance, multi-language network signal analyser, dedicated to surveying the global LTE Cat M, LTE NB IoT* & 2G/GSM networks**. Signal strength and cell parameters can be detected on LTE Cat M and on 2G/GSM.
  • Page 6: Specifications

    SNYPER-LTEM (GL) User Manual Specifications Table 1. Specifications of SNYPER-LTEM (GL) SNYPER-LTEM (GL) 2G supported bands: B2 (1900) / B3 (1800) / B5 (850) / B8 (900) MHz B1 (2100) / B2 (1900) / B3(1800) / B4 (AWS 1700) / B5 (850) / B8 (900)
  • Page 7: Operating Frequencies Detail

    SNYPER-LTEM (GL) User Manual Operating Frequencies Detail The operating frequencies in EGSM900, DCS1800 and WDCMA modes are set compliant to the 3GPP and WCDMA specifications. Table 2. Operating frequencies detail Uplink Downlink Tx - Rx EARFCN EARFCM Band Common Name...
  • Page 8: Product Images

    SNYPER-LTEM (GL) User Manual Product Images Figure 2. Front view of the SNYPER-LTEM (GL) Charge Status LED 320 x 240 LCD Display (51 x 38mm viewing area) UP Button OK Button RIGHT Button LEFT Button BACK Button ON/OFF Button...
  • Page 9 SNYPER-LTEM (GL) User Manual Figure 3. Bottom view of the SNYPER-LTEM (GL) SIM Slot USB Mini Charging Socket Figure 4. Top view of the SNYPER-LTM (GL) - without antenna Antenna Connector - SMA Female Siretta Ltd sales +44(0)118 976 9000...
  • Page 10: First Time Use Of The Snyper-Ltem (Gl)

    SNYPER-LTEM (GL) User Manual First Time Use of SNYPER-LTEM (GL) » Your SNYPER needs to be charged for 4 - 6 hours before initial use. To charge your SNYPER, connect to any convenient USB power source using the mains adaptor supplied, car charger or a USB port on a device such as a computer using the supplied cable.
  • Page 11: Charging And Battery Status

    SNYPER-LTEM (GL) User Manual Charging and Battery Status Approximately 4 - 6 hours are needed to fully charge your SNYPER. The device will be charged when it is plugged into a USB power source - the supplied AC adaptor, or the USB host port on a PC or similar.
  • Page 12: Main Menu

    SNYPER-LTEM (GL) User Manual Main Menu Your SNYPER main menu has 7 menus (as shown below in figure 8), these can be selected using the UP/DOWN buttons. Once the chosen menu is highlighted, click OK. Press the BACK button to return to the main menu.
  • Page 13: Saved Results Menu

    SNYPER-LTEM (GL) User Manual Saved Results The ‘Saved Surveys’ menu allows you to review saved survey results on your SNYPER product. The SNYPER-LTEM (GL) can store 1 survey on the device. Step 1. Press OK to view the saved survey results.
  • Page 14 SNYPER-LTEM (GL) User Manual Show Saved Results Highlight ‘Show Results’ and press OK. The SNYPER will display all results with numbered cells from strongest to weakest. To switch between all signals found in the survey, use the LEFT/RIGHT buttons.
  • Page 15: Survey Menu

    SNYPER-LTEM (GL) User Manual Survey Menu Performing a Survey To perform a survey on your SNYPER, follow the steps below: Step 1. Select ‘Survey’ from the main menu and press OK. Step 2. Use the UP/DOWN buttons to select what survey you would like to perform and press OK.
  • Page 16 SNYPER-LTEM (GL) User Manual Step 3. Press OK to be taken to the post survey menu as shown below in figure 14. Figure 14. Selecting survey to perform Show Results Highlight ‘Show Results’ and press OK. The SNYPER will display all results with numbered cells from strongest to weakest.
  • Page 17 SNYPER-LTEM (GL) User Manual Show Summary Highlight ‘Show Summary’ and press OK. The SNYPER will display the number of cells by each network in frequency bands. Use the LEFT/RIGHT buttons to switch between signal strengths received on the device.
  • Page 18: Setup Menu

    SNYPER-LTEM (GL) User Manual Setup Menu By selecting ‘Setup’ from the main menu, the following setup changes can be made (as shown below in figure 17). To select a sub menu use the UP/DOWN button until relevant menu is highlighted, then use the LEFT/RIGHT buttons to amend preference.
  • Page 19 SNYPER-LTEM (GL) User Manual SNYPER Modes The ‘Mode’ option determines the operation mode of your SNYPER when performing a survey. There are 3 options: Standard, Advanced or Engineer - each will display a different range of results once a survey has been performed.
  • Page 20 SNYPER-LTEM (GL) User Manual Table 3 (continued). Breakdown of information provided ✓ GSM ✓ CAT M ✓ NB IoT Standard Advanced Engineer ARFCN - Absolute Radio Frequency Channel Number being ✓ ✓ ✓ received EARFCN - E-UTRA Absolute Radio Frequency Channel ✓...
  • Page 21: About Menu

    SNYPER-LTEM (GL) User Manual About Menu By selecting ‘About’ from the main menu, information about your SNYPER product will be displayed (as shown below in figure 18). Figure 18. ‘About’ screen HW: SNYPER-LTEM (GL) hardware version. BV: Battery voltage.
  • Page 22: Pc Connect

    SNYPER-LTEM (GL) User Manual PC Connect The PC Connect feature allows you to download stored surveys onto your PC. The data is downloaded to your PC in .CSV and .HTML format. The downloaded data will include GSM and LTE survey results.
  • Page 23 SNYPER-LTEM (GL) User Manual Viewing Results Select the results you wish to view in either .CSV or .HTM format. Figure 21. .CSV data download Figure 22. .HTML data download Siretta Ltd sales +44(0)118 976 9000 Basingstoke Road email sales@siretta.com Registered in England No.
  • Page 24: Power Off

    SNYPER-LTEM (GL) User Manual Power Off After use, remember to power off your SNYPER. The device can be powered off in the following 2 ways: » Selecting the ‘Power Off’ option from the main menu. The device will display a power off message as shown below in figure 24.
  • Page 25: Updating The Snyper Software

    SNYPER-LTEM (GL) User Manual Updating the SNYPER Software From time to time Siretta may make software updates available for the SNYPER-LTEM (GL). Normally, these software updates will be made available as a complimentary service on the Siretta website. Updated software may contain improvements and/or new features.
  • Page 26 SNYPER-LTEM (GL) User Manual Step 3. Connect supplied USB cable to your SNYPER and PC. Step 4. Select ‘PC Connect’ from the main menu, and use the RIGHT button to enable PC Connect. Windows Explorer will open automatically. If Windows explorer does not open automatically, open it by pressing and holding the Windows key and ‘e’.
  • Page 27 SNYPER-LTEM (GL) User Manual Step 8. You will be prompted to confirm the software update. Click the RIGHT button to confirm performing a software update. Figure 29. Confirm software update Once you have confirmed the software update, the process will begin automatically.
  • Page 28: Safety Product And Care

    SNYPER-LTEM (GL) User Manual Safety and Product Care General Precautions Do not exceed the environmental and electrical limits as specified. » » Avoid exposing your SNYPER product to lit cigarettes, naked flames or to extreme hot or cold temperatures.
  • Page 29: Safety Recommendations

    SNYPER-LTEM (GL) User Manual Safety Recommendations PLEASE READ CAREFULLY Be sure the use of this product is allowed in the country intended and the environment required. The use of this product may be dangerous and has to be used with caution in the following areas: »...
  • Page 30: Copyright

    SNYPER-LTEM (GL) User Manual Copyright Information Copyright Declaration © 2021 Siretta Ltd, All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without the written permission of Siretta Ltd.
  • Page 31: Disclaimer

    SNYPER-LTEM (GL) User Manual Disclaimer The information contained in this document is proprietary to Siretta Ltd. Siretta Ltd has made every effort to ensure that the information contained within this document is accurate. Siretta Ltd does not make any warranty as to the information contained within this document and does not accept any liability for any injury, loss or damage of any kind incurred using this information.
  • Page 32: Definitions

    SNYPER-LTEM (GL) User Manual Definitions Term Definition Mobile Network Operator 2nd Generation Mobile RSSI Received Signal Strength Indicator Telecommunications Basestation Scrambling Code 3rd Generation Mobile Subscriber Identity Module Telecommunications Sub Miniature version A 4th Generation Mobile Telecommunications Tracking Area Code (Assigned by MNO)
  • Page 33 +44 (0)118 976 9000 email sales@siretta.com www.siretta.com Siretta Ltd Basingstoke Road Spencers Wood Reading Berkshire RG7 1PW United Kingdom Company No. 08405712 VAT Registration No. GB163 04 0349 Rev 1.1 - March 2021...

Table of Contents